8
EN
4.2. Housing Dimensions
1 = Laser Diode/Laser Aperture
2 = Receiver Diode
3 = Laser Warning Sign
4 = Name Plate incl. Laser
Warning Sign
4.3. The Control Panel
Display
Control key
A warning triangle in the display indicates that the
Sensor receives a lot of light, e.g. through a glossy
surface of the object. The measurement value could
be around 400 mm too low in this case. To find a
remedy, see the mounting instructions in case of
glossy surfaces.
5. Installation Instructions
All applicable electrical and mechanical regulations, standards and safety precautions must be adhered to
when installing and operating the Sensor. The Sensor must be protected against mechanical influences. Install
the device such that its installation position cannot be inadvertently changed. The wenglor mounting system is
recommended for installing the Sensor. In order to obtain best possible results, the device’s optics should be
aligned at a right angle to the direction in which the objects are conveyed.
At brilliant surfaces, mount the Sensor in an angle of 5° to avoid
a direct reflexion beam into the lens.
SENSOR