7.2.2. Display Intensity
Intensity
Set the display intensity
Min
Normal
Max
Power save
Screensaver
Min:
The intensity of the display is set to a minimum value.
Normal:
The intensity of the display is set to a medium value.
Max:
The intensity of the display is set to a maximum value.
Power save: The display switches off after one minute without a button being
pressed and automatically switches back on when a button is pressed.
Screensaver: The colors of the display are inverted every minute.
7.3. Offset
The offset function is used to change the current measured value to a defined value.
Offset
Change the measured value
Default
Change
Apply
3
Back
7
Run
Default:
Learn offset value. The current measured value is adopted as the
default offset value by pressing the “T”. The offset value is set to 0
by pressing the “Z” button.
Change:
Change the value of the offset. By pressing the “+” button or
the “–” button, the value set in the menu item “Default” can be
changed.
Apply:
Accept the offset value set in the menu item “Default” as the mea-
sured value. By pressing the “T” button, the offset value set in the
menu item “Default” is adopted as the displayed measured value.
The offset function is reset by pressing the “Z” button, and the
actual distance is displayed.
The currently set default offset value is displayed in µm.
Example of the measured value for the offset function:
In the diagram the Sensor measures a distance of 500 mm. After application of the offset with offset value of
0 mm, the measured value at 500 mm becomes the measured value 0 mm.
500 mm
Application off offset with
offset value 0 mm
Real Distance
Object