Installation Instructions
8
3.4. Control Panel
On the control panel you find the Plus key and the Minus key, several LEDs and the rotary selector switch.
The rotary selector switch is used for choosing the setting- and operation functions.
= Minus key (with LED)
= Plus key (with LED)
I-LED (yellow)
= Current output
U-LED (yellow)
= Voltage Output. Brightness is proportional to the output voltage
F-LED (rot)
= Error Output
Ý
= Rotary selector switch
RUN
= Sensor operation
TEACH
= Teach measurement range
FILTER ADJUST
= Filter adjustment
DCM/SCM/LCM
= Switching Default Capture Mode/Short Capture Mode/Long
Capture Mode
RES./SPEED-MODE = Switch Resolution/Speed
RxD/La Mode
= Switching RS-232 Interface/Emitted Light can be switched off
U/I Mode
= Switching 0…10 V/4…20 mA
RESET
= Reset
4. Installation Instructions
During use of the sensors, applicable electrical and mechanical regulations, standards and safety precautions
must be adhered to. The sensor has to be protected against mechanical influences.
In case of very glossy surfaces the sensor has to be mounted slightly inclined and has to be mounted on a
plane surface (approx. 5°), to inhibit a direct reflection of the laser beam into the optics.
5. Initial Operation
Please control the proper connection of all conductors.
Impress a supply voltage of 18…30 V DC with ripple of < 10 % (within the indicated voltage range).
The settings can be operated either with the RS-232 interface or manually.
6. Function
The sensor uses a high-resolution CMOS line array and DSP technology, virtually eliminating material, color
and brightness related measurement value differences. Alternatively high speed (Speed-Mode) or high
resolution (Resolution-Mode) are adjustable. Integrated analogue output can be configured for voltage
0…10 V or current 4…20 mA, error output and RS-232 interface, Teach-In, Error Output and filter functions.
DCM
LCM
SCM
FILTER
ADJUST
TEACH
RUN
RESET
U/I MODE
RxD
La MODE
RES./SPEED MODE
I
U