TRANSPORTATION & STORAGE
WARNING!
Avoid direct sunlight inside a vehicle. If the generator is left in an enclosed vehicle for many
hours, the high temperature could cause the fuel to vaporize and result in a possible explosion.
WARNING!
Store the generator upright in a cool and dry location, away from sources of heat, open flames,
sparks or pilot lights.
TRANSPORTING THE GENERATOR
To prevent fuel spillage when transporting, be sure to perform the following:
1. Tighten the fuel cap.
2. Flip the engine switch to the OFF position.
3. Drain the fuel tank if possible.
Refer to section, “Draining the Fuel Tank.”
4. Keep the generator upright. Never place the generator on its side or upside down - doing so could damage the
internal components of the generator and make it difficult to start.
STORING THE GENERATOR
Shut off the generator and allow the unit to cool to room temperature before storing it. NEVER place any type of
storage cover on the generator while it is still hot. Do not obstruct any ventilation openings.
Follow the procedures below for properly storing your generator. We highly recommend running your generator
once a month for 20 to 30 minutes. Plug in a small load in to ensure there is proper power output.
PRODUCT DISPOSAL
Do not dispose of used generator or parts with your household waste. This product contains electrical or electronic
components that should be recycled. Please take this product to your local recycling facility for responsible disposal
to minimize its environmental impact.
Do not dispose of used oil or fuel in the trash or down a drain. Please contact your local recycling center or auto
garage to arrange proper oil/fuel disposal.
For Short Periods (30 to 60 Days):
• Drain the carburetor.
Refer to page 30, “Draining the
Carburetor.”
• Disconnect the negative lead from the battery.
• Add fuel stabilizer:
Follow the suggested portions and
instructions of your preferred stabilizer. Run the engine for
15 to 20 minutes, allowing the fuel stabilizer to mix with the
gasoline and circulate through the carburetor, and then top
off with fuel. Filling the fuel tank full reduces the amount of
air in the tank and helps fight deterioration of fuel.
For Extended Periods (Over 60 Days):
• Disconnect the negative lead from the
battery.
• Drain the fuel tank and carburetor (see
“Draining the Fuel Tank”). Never store
generator with fuel in the tank for more
than two months.
• Change the engine oil (see “CHANGING
OIL”).
Please recycle the packaging and electronic components where facilities exist. Please contact your
local auto garage or recycling facility to properly dispose of oil/fuel.