This is a guide to replacing a broken spark plug boot for your WEN 56380i Inverter Generator.
This guide is best used in conjunction with the 56380i manual, included as a physical copy
with your unit and available on the WEN website page for the 56380i (link
), by clicking
“Click here to view the product manual”.
If at any point you need assistance, have questions, or want to order parts, call WEN customer
service at 1-800-232-1195, M-F, 8-5 Central Time, or email
If replacing any parts, use only genuine replacement parts purchased from WEN Products. Use of replacement
parts not sold by WEN Products will void your warranty and could lead to decreased performance or injury.
TABLE OF CONTENTS
Tools needed
1
Replacing the broken spark plug boot
1
TOOLS NEEDED
•
Pair of pliers
•
Phillips-head screwdriver
ENSURE THAT THE ENGINE IS COOL BEFORE BEGINNING ANY MAINTENANCE OR REPAIR WORK. FOLLOW
ALL SAFETY PROCEDURES LISTED IN YOUR OWNER’S MANUAL. USE COMMON SENSE. AVOID INJURY.
REPLACING THE BROKEN SPARK PLUG BOOT
1. Make sure the engine is cool.
2. Use the Phillips-head screwdriver to remove the two
screws shown at right.
3. Remove the panel.
4. Locate the spark plug boot. Move the ignition coil (with
spark plug boot still attached) out of the way.
Date last modified: 2020/08/14