WPC-18000

Figure 1

Owner’s Manual

Specifi cati ons

WPC-18000

Model No.

Power Supply 

(Phase-V-Hz)              

Cooling Capacity 

(Btu/h)

Power Consumpti on

   

(Watt s)

Rated Current 

(Amps)

WPC-18000 1Phases - 220V - 60Hz  

60000

6.5kW

30.2A

Model No.

Weight (Net / Gross) 

Lbs(kg)

Operati ng Ambient        

Temperature Range 

Dimensions  

W x D x H - in. (mm)

WPC-18000

 672/728lbs.

(305/330kg)

64~113 

°F 

(18~45 

°C

)

29.5 x 62.1 x 58.1

(750 x 1578 x 1478 )

Please read and save these instructions. Read carefully before attempting to assemble, install, oper-

ate or maintain the product described.

Protect yourself  and others by observing all safety information. Failure to comply with instructions 

could result in personal injury and / or property damage! Retain instructions for future reference.

High Capacity Air Conditioner 

(For Indoor & Outdoor)

by

AmeriCool

 Portable Air Conditi oners are specialized for 

“SPOT COOLING” where central cooling is impracti cal. 

AmeriCool

 air conditi oners can also be used in enclosed areas 

just like conventi onal air conditi oners. Simple digital controller 
and self-diagnosti c functi ons allow users to easily operate 

the unit. Built-in Caster wheels enable users to move the 
unit without any hassle. The unit can be installed in 5 minutes 

and does not require any extra materials or certi fi ed technician 
for installati on. 

AmeriCool

 Portable Air Conditi oner, anywhere, everywhere. 

Plug-and-Go!

Aft er unpacking the unit, carefully inspect unit for any damage that may have occurred during transit. 
Check for any loose, missing, or damaged parts.

Descripti on

Unpacking

Содержание AmeriCool WPC-18000

Страница 1: ...ry and or property damage Retain instructions for future reference High Capacity Air Conditioner For Indoor Outdoor by AmeriCool Portable Air Conditioners are specialized for SPOT COOLING where centra...

Страница 2: ...only Leave unit in an upright position for at least 3 hours before first use 2 Always place the unit on an even level surface 3 Ensure the unit is connected to a grounded power supply of the correct...

Страница 3: ...be used with the product at all times When the filters are removed for cleaning always ensure that the unit has been turned off and unplugged from the electrical outlet 19 Regularly clean the filters...

Страница 4: ...ght Side View Controls Hot Air Exhaust Top Cover Electrical Panel Caster Air Inlet I BOLT Condensate outlet Cold Air Inlet Cold Air Inlet Filter Cold Air Exhaust Filter Handle Emergency Stop Controls...

Страница 5: ...as possible to the desired space without any excessive turns and pinches 3 Please avoid any objects or walls at the end of the duct The Return Air In duct connection is labeled AIR IN The diameter of...

Страница 6: ...he unit is equipped with an approved NEMA plug configuration The appropriate outlet must be used for each plug type WARNINGS REGARDING PROPER LOCATION FOR INSTALLATION Do not use the unit in explosive...

Страница 7: ...Activates Spot Cooling mode when the button is pressed for 1 second Compressor can be switched on off 4 ROOM COOL BUTTON Activates Room Cooling mode when the button is pressed for 1 second Compressor...

Страница 8: ...TE Canadian version shows the temperature in Celsius 8 TARGET TEMP Displays target temperature OFF TIMER Press BLOWER Button and SPOT COOL Button simultaneously for 2 seconds to set off timer Press UP...

Страница 9: ...urchase receipt as proof of purchase to this instruction manual for future reference To ensure your product is covered by warranty the complete faulty product along with your original purchase receipt...

Страница 10: ...s manual for future reference and keep sales receipt as proof of purchase SELF DIAGNOSTIC CODES See Table 1 The alarm will activate when the unit detects any abnormality It will show certain alarm cod...

Страница 11: ...duct is not blocked or kinked Ensure the working tem perature is below 45 C Abnormal temperature TH1 Outlet tempera ture sensor has a loose or broken connection Contact a qualified service agent Abnor...

Страница 12: ...S NO 1 COMP Spark Arrestor FND PS HP COM COM EXT FU FT CO COM L 1A N 1A L H COM COM L H COM CP N 1 L 1 COM CO Power Remote Control Option EXT COM FUSE FUSE HIGH PRESSURE SWITCH MC 2 OCR 2 L 2A N 2A C...

Страница 13: ...Compressor will not work if the unit is turned on and off too quickly 2 Wait 2 minutes after unit is turned off before turning the unit back on 3 Ambient temperature is too high 3 The temperature of t...

Страница 14: ...meriCool Technical Support at 888 726 6158 Please have the following informa tion available BEFORE calling the Technical Support Department a Your name and address b The serial number of the unit c Wh...

Страница 15: ...ions or alterations to the Products vii use with parts or devices not supplied or approved by AmeriCool viii improper installation or service ix shipping damage to any units or spare parts during ship...

Отзывы: