Weltem AMEARICOOL WPH-3000 Скачать руководство пользователя страница 1

1

Owner’s Manual

WPC-3000, WPC-4000, WPC-5000

Please read and save these instructions. Read carefully before attempting to assemble, install, oper-

ate or maintain the product described.

Protect yourself  and others by observing all safety information. Failure to comply with instructions 

could result in personal injury and / or property damage! Retain instructions for future reference.

AmeriCool by Weltem Portable Heat Pump feature spot 

cooling/heati ng for large areas where cooling/heati ng of the 
enti re area is not practi cal. A dedicated spot cooling/heati ng 
thermostat controls the unit in this applicati on.
This unit can also be used in smaller areas for room cooling/
heati ng. A control panel provides ease of use and contains 
a  self-diagnosti c  functi on  and  display,  showing  operati ng 
modes, room and set temperatures, and faults. 
If an abnormal operati on occurs, a visual display of the fault 
is  shown.  Caster  wheels  are  included  for  easy  portability. 
Suitable applicati ons include: a factory or work place, indus-
trial  kitchen,  computer  room,  emergency  cooling/heati ng, 
outdoor event, supplement cooling / heati ng etc.

Aft er unpacking the unit, carefully inspect unit for any damage that may have occurred during 
transit. Check for any loose, missing, or damaged parts.

Descripti on

Unpacking

Owner’s Manual

Specifi cati ons

WPH-3000

Portable Heat Pump

by

WPH-3000

Figure 1

Model No.

Power Supply Ph-V-Hz

Cooling Capacity 

Btu/h

Power Consump-

ti on Watt s

Rated Current 

Amps

EER Btu/

Wh

WPH-3000

Single Phase, 

115V, 60Hz

13,200(Cooling)

14,300(Heati ng)

0.94kW(Cooling)

0.95kW(Heatling)

8.58A (Cooling)

8.53A(Heatling)

11.0

Model No.

Power Cord Gauge 

AWG

Power Cord 

Length ft 

Dimensions 

W x D x H - in. (mm)

WPH-3000

12

6

20.6x 26.4 x 41.1

(523x 670 x 1044)

Содержание AMEARICOOL WPH-3000

Страница 1: ...isplay showing operating modes room and set temperatures and faults If an abnormal operation occurs a visual display of the fault is shown Caster wheels are included for easy portability Suitable applications include a factory or work place indus trial kitchen computer room emergency cooling heating outdoor event supplement cooling heating etc After unpacking the unit carefully inspect unit for an...

Страница 2: ...trol Self diagnostic function Six speed fan Op tional drain pump kit Washable filters F C display Off timer Auto fan speed option Thank you for selecting this Weltem Portable Heat pump It provides you with spot cool ing heating for large areas where cooling heating of an entire area is not practical or possible Please read this manual before installing the WPH 3000 as it provides impor tant inform...

Страница 3: ...n objects on the unit 11 DO NOT operate the unit with wet or damp hands 12 DO NOT allow chemical substances to come into contact with the unit 13 DO NOT operate the unit in the presence of flammable substances or vapors such as alcohols pesticides gasoline etc 14 DO NOT use the plug to start and to stop the unit Always use the control panel to start and to stop the unit 15 Always turn off the unit...

Страница 4: ...ed 22 Only use in the upright position on an even flat surface Unit must be positioned at least 24 inches 60 cm from the nearest object in any direction 23 Stop operation immediately if abnormal noise or odor is noticed Contact a local service center 24 Appliance is not to used by children or persons with reduced physical sensory or mental capabilities or lack of experience and knowledge unless th...

Страница 5: ...ith the top fan exhaust flange to install the top fan exhaust flange on the unit as shown in Figure 6 TOP FAN EXHAUST FLANGE Figure 6 Figure 7 Figure 8 A B C Condenser plenum can be purchased separately Condenser plenum fits over the condenser to duct condenser air to the unit to improve cooling efficiency 1 Remove the Filter A 2 Check the Filter C is inserted properly in Condenser plenum B 3 Inst...

Страница 6: ...et is free of dirt dust oil water or any other foreign material The unit is equipped with an approved NEMA plug configuration WARNINGS REGARDING PROPER LOCATION FOR INSTALLATION Do not use the unit in explosive environments or in areas where flammable gas leakage may occur Do not use the unit in areas where it will be exposed to rain or water Do not use the unit in a corrosive atmosphere Do not us...

Страница 7: ...r by pressing this button shortly When IN lamp is on inlet temperature sensor works so it is used to control inside of a room When OUT lamp is on outlet temperature sensor works so it is used to provide cool air or hot air directly to people or material By pressing this button for 2 seconds SET lamp will be on and SET mode activates Then set the target temperature by pressing UP DOWN BUTTONS After...

Страница 8: ...TTON together for 2 seconds Choose 7 by pressing UP DOWN BUTTON Choose 0 by pressing UP DOWN BUTTON Press MODE BUTTON for 2 seconds then figure will change to C Displays the unit set temperature When OUT lamp is on in TEMP SELECT always set TARGET TEMP value 32 F 0 C for COOL mode and 122 F 50 C for HEAT mode When IN lamp is on in TEMP SELECT recommendable TARGET TEMP is between 64 F and 113 F 18 ...

Страница 9: ... in the guide and slide the filter up until the bottom of the filter clears the frame Then push the bottom of filter into the guide and let filter gently fall inside the guide NOTE For effective cooling clean the filter at least every 2 weeks For your convenience record the complete model number and product name located on the Product Identification Plate the purchase date purchase location serial...

Страница 10: ... occurs and a code is displayed on the control panel The compressor and condenser fan motor will stop operating The evaporator fan will con tinue to run for 3 minutes If the fault is rectified within 3 minutes the unit will resume opera tion If the fault persists for more than 3 minutes the evaporator fan also stops The fault must be rectified before the unit can resume normal operation There are ...

Страница 11: ...r has a loose or broken connection Contact a qualified service agent Contact a qualified service agent Compressor overloaded Condenser fan alarm Evaporator fan alarm Defective compressor Ambient temperature is too high Replace compressor Do not use the air conditioner if ambient temperature is higher than 113 45 Contact a qualified service agent Contact a qualified service agent Voltage of condens...

Страница 12: ...age of evaporator fan is lower than normal Evaporator fan is failure Unstable voltage supply Drain pump Drain pump defective or improper hose connection The alarm light is activated if abnormal operation occurs and a code is displayed on the control panel The compressor and condenser fan motor will stop operating The evaporator fan will continue to run for three minutes If the fault is rectified w...

Страница 13: ... Wiring Diagram 136 116 1 2 3 4 5 6 7 8 2 1 재질 은무데드롱 25미크론 2 인쇄방법 씨링인쇄 3 인쇄색상 흑색 1도 4 표면처리 라미네이팅 OPP코팅 5 인쇄기준 도면 및 설계 제공 필름 6 외곽의 치수선 붉은선 은 인쇄후 절단선임 WPH 3 4 5 V1 14 Power 1P AC 115V 60Hz 1P AC 208 230V 50 60Hz Figure 13 WPH 3000 ...

Страница 14: ... properly cooled if the filter is dirty and not regularly cleaned 1 Clean the filter 2 Compressor will not work if the unit is turned off and on quickly 2 Wait 2 minutes after unit is turned off before turning the unit back on 3 The ambient air tem perature may be too high 3 The temperature of the com pressor can be higher when the ambient temperature is too high The compressor will not work unles...

Страница 15: ... Heat Pump Technical Support at 888 726 6158 Please have the following information available BEFORE calling the Technical Support De partment a Your name and address b The serial number of the unit c Where and when the unit was purchased d All of the model information about your AmeriCool by Weltem Portable Heat Pump e Any information on the failure including LED s that may or may not be illuminat...

Страница 16: ...on vi modifications or alterations to the Products vii use with parts or devices not supplied or approved by AmeriCool viii improper installation or service ix shipping damage to any units or spare parts during shipping This includes and is not limited to compres sors evaporators and condenser coils This warranty shall extend only to the original end user and shall be void if any labels or other i...

Отзывы: