WARNING: 

ELECTRIC 
SHOCK HAZARD 

 

All servicing requiring 
access to non-insulated 
electrical components 
must be performed by a 
factory authorized        
technician. 
DO NOT open any access 
panel which requires the 
use of tools.  Failure to 
follow this warning can 
result in severe electrical 
shock.

 

 

CAUTION: 

RISK OF 
DAMAGE 

 

DO NOT connect or energize 
this appliance until all        
installation instructions are 
read and followed.  Damage 
to the  appliance will result if 
these instructions are not  
followed. 

 

CAUTION: 

ELECTRICAL 
SHOCK  HAZARD 

 

The ground lug of this         
appliance must be connected 
to a suitable building ground. 
 

IMPORTANT: 

Contact a licensed electrician 
to install and connect         
electrical power to the         
appliance. 

 

IMPORTANT: 

Damage due to being 
connected to the wrong     
voltage or phase is NOT    
covered by warranty. 

 

 

 INSTALLATION 

ELECTRICAL INSTALLATION

 

 

1.  Refer to the nameplate.  Verify the electrical service power.       
 

Voltage and phase must match the nameplate specifications.     

 

Wiring the unit to the wrong voltage can  severely damage the unit 

 

or cause noticeably decreased performance.   

 

2.  Available electrical service amperage must meet or exceed the  
 

specifications listed on the specification sheet provided with the 

 

unit.  Connect to the terminal block in the control unit.  Wiring must 

 

be secured to the control unit with an appropriate strain relief 

 

(provided by installer). 

 

 IMPORTANT:

   

 

L1 to L2 must be 208 to 240 volts AC. 

 

L2 to Neutral must be 120 volts AC 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

3.  Tank and control unit must be connected to an appropriate building 
 

ground.  Ground connection will be marked “GND” or “       ” . 

 
 

NOTE: 

 Wire gauge, insulation type and temperature rating , as 

 

well as type, size and construction of conduit, must meet or exceed 

 

applicable specifications of local codes and of the National        

 Electrical 

Code. 

 
 

L1

L2

N

208V

or

240V

120V

M

406 p/

n 2M

-3049

42  

Owners M

anual HRCP-Serie

s

 Hea

ted Cold 

Pan

s

 

Содержание HRCP7200

Страница 1: ...re available from your WELLS DEALER THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR INSTALLING THIS APPLIANCE Contact your WELLS DEALER if you have any questions concerning installatio...

Страница 2: ...ult of normal use within the time period and limitations defined in this warranty will at Wells discretion have the parts replaced or repaired by Wells or a Wells authorized service agency THIS WARRAN...

Страница 3: ...LE OF CONTENTS INTRODUCTION 1 MODEL VOLTS KW 1 AMPS HP VOLTS 1 AMPS REFRIGERANT POWER SUPPLY REQUIREMENT HRCP 7200 HRCP 7200ST 208 240 60Hz 1 9 2 5 9 1 10 4 1 4 120 60Hz 4 9 R 134a 3 wire L1 L2 N 10 A...

Страница 4: ...OPERATION WHEN WATER REMAINS IN PAN WELLS MANUFACTURING COMPANY ST LOUIS MO USA DRAIN DRAIN SCREEN INDICATOR COLD OPERATION LCD READOUT SET KEY KEY INCREASE KEY INCREASE KEY DECREASE SELECTOR COLD OFF...

Страница 5: ...operate this appliance if the control panel is damaged Call your Authorized Wells Service Agent for service The technical content of this manual including any wiring diagrams schematics parts breakdo...

Страница 6: ...liance performance tested to NSF Standard 7 for storage of potentially hazardous foods This appliance meets NSF Standard 7 only when the pan rails are installed in the lowest position HRCP units are E...

Страница 7: ...on Instruction Sheet packed with the appliance before starting any installation Read and understand all labels and diagrams attached to the appliance Carefully account for all components and accessori...

Страница 8: ...L INSTALLATION 1 Refer to the nameplate Verify the electrical service power Voltage and phase must match the nameplate specifications Wiring the unit to the wrong voltage can severely damage the unit...

Страница 9: ...er supply line with average pressure between 20 PSI and 90 PSI If your water pressure exceeds 90 PSI at anytime a pressure regulator must be installed in the water supply line to limit the pressure to...

Страница 10: ...s b Install the end rails then any intermediate rails 5 Install pans or insets on the pan rails IMPORTANT Always use a pan or inset Never place food directly into the tank 6 Cover pans and insets to m...

Страница 11: ...PORTANT For NSF 7 operation use 12 x 20 x 4 deep pans and use the lower pan rail supports which are recessed 3 from tank top SHUT DOWN PROCEDURE 1 Turn SELECTOR SWITCH to OFF The white COLD indicator...

Страница 12: ...element cover may be washed in a sink or dishwasher Allow to dry thoroughly then reinstall 5 Check drain screen clean if necessary and reinstall 6 Periodically inspect warmer flange to counter seal Re...

Страница 13: ...s Service Agency for repairs Unit doesn t cool COLD Mode Selector switch not set to COLD Set to COLD Tank too hot Allow to cool to 100 F or less Condenser cooling louvers or coil plugged Clean condens...

Страница 14: ...ar motion along the longest axis of the equipment 4 Use only non chloride and non ammonia cleansers a DO NOT use any cleanser listed as chlorinated b DO NOT use any cleanser listing ammonia or ammoniu...

Страница 15: ...r to dissolve cleaner Cover tank 4 Allow solution to soak at least one hour or overnight for heavy scale buildup 5 After soak period turn control to OFF position 6 Drain hot water from pans Scrub with...

Страница 16: ...s operation IMPORTANT The fins of the condenser coil are delicate and easily damaged Use care to brush only in a vertical motion to avoid damaging the coil fins 4 Wipe the fan blades to remove accumul...

Страница 17: ...2 5 10 4 9 0 208 240 7100 5 5 120 1 4 R 134 A 15 BLACK WATER SUPPLY MANUAL RESET OVER TEMP CUTOUT THERMOSTAT 2 31 IMMERSION ELEMENT SECOND ELEMENT FOR HRCP 7400 THRU 7600 ONLY 32 POWER RELAY WATER FIL...

Страница 18: ...M406 p n 2M 304942 Owners Manual HRCP Series Heated Cold Pans PARTS LIST 16...

Страница 19: ..._____ _____ _________ EQUIPMENT MODEL NO _______________ EQUIPMENT SERIAL NO _______________ VOLTAGE check one 208 240 ACCESSORY PARTS SERVICE 17 IMPORTANT Use only factory authorized service parts an...

Страница 20: ...WELLS MANUFACTURING 265 Hobson Street Smithville Tennessee 37166 telephone 314 678 6314 fax 314 781 2714 www wells mfg com...

Отзывы:

Похожие инструкции для HRCP7200