FIELD TRIAL PROTOTYPE SAMPLES

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Document No: 

WT 9437

 

Issue Date: August 2020 

 
 
 
 
 

® is a registered Trade Mark of Wellington Drive Technologies

 

 

Содержание Connect Monitor

Страница 1: ...w Zealand PO Box 302 533 North Harbour North Shore 0751 New Zealand P 64 9 477 0415 Fax 64 9 414 6591 E info wdtl com www wdtl com Connect Monitor Manual FIELD TRIAL PROTOTYPE SAMPLES Document No WT 9437 Issue Date August 2020 is a registered Trade Mark of Wellington Drive Technologies ...

Страница 2: ...ons and configurations of the Connect Monitor where such a relationship may exist no liability responsibility or risk is accepted in determining if the Connect Monitor is fit for purpose for any particular application No liability responsibility or risk is accepted by Wellington Drive Technologies Limited for the correct operational function of any particular installation or configuration The Conn...

Страница 3: ... as this may damage the housing leading to unsafe operation Exposure to such chemicals invalidates the warranty Temperature The Connect Monitor must only be subjected to temperatures as specified in the Datasheet and the Technical Specification section of this manual Exceeding these ranges in operation installation transportation or storage will invalidate the warranty and may damage electronic ci...

Страница 4: ...ty to existing refrigeration equipment in the market It provides telemetry connectivity asset tracking and proximity based marketing functionality Another unique feature is wireless connectivity to a mobile app that gives authorized Service Technicians full wireless access to data logging and troubleshooting Mobile app with intuitive touch screen interface Wireless data logging and diagnostic cont...

Страница 5: ...uetooth connectivity These steps are marked with the NFC symbol in the process diagram If no suitable mobile phones are available at installation site Bluetooth connectivity needs to be activated in warehouse prior to field deployment Bluetooth deactivation for transport is not required except when in accordance to shipment compliance Please consult your logistics specialist for requirements Welli...

Страница 6: ... following data must be configured to ensure data collection and storage for the Connect Monitor Manufacturer Id Owner Id Brand Id Asset Number The following data should also be configured when Connect Monitor is installed into an asset Model Serial Number When an asset fitted with Connect Monitor is delivered to a field location or installed in outlet the following data should be entered through ...

Страница 7: ...NGE side of the cooler When possible mount Connect Monitor away from LED panels to improve temperature measurement accuracy Hinge side placement reduces the visual impact and likelihood of Connect Monitor being accidentally knocked out of place This ensures the Connect Monitor reads the return air temperature correctly Installation ABOVE the evaporator inlet may result in incorrect temperature rea...

Страница 8: ...vaporator inlet When possible mount Connect Monitor away from LED panels to improve temperature measurement accuracy This ensures the Connect Monitor reads the return air temperature correctly Installation not in the airflow stream may result in incorrect temperature reading due to placement in an air circulation dead space that is often different to the overall cabinet temperature ...

Страница 9: ...and hence be visible The front edge of the Connect Monitor should be installed within 70 mm 2 3 4 of the point where the door seals touch the cabinet wall This is critical to ensure door opening detection If you cannot see the barcode label after installation Connect Monitor is installed facing the wrong way and door openings will not be detected This ensures accurate door detection If the device ...

Страница 10: ...alcohol wipe STEP 2 Wait for surface to dry before attaching Connect Monitor STEP 3 Expose adhesive on the back of the device by removing liner STEP 4 Firmly press Connect Monitor onto mounting surface and hold for at least 5 seconds If cabinet is cold ensure there is no condensation on the surface prior to attaching the device ...

Страница 11: ... FIELD TRIAL PROTOTYPE SAMPLES 11 STEP 5 optional Insert the two 8 self drilling screws provided into the mounting holes Use a standard Phillips head driver to secure screws into the mounting surface screws will pierce foam tape and seal ...

Страница 12: ...Check for updates in the App Store or Google Play Detailed instructions on how to install and activate Connect Field app can be found in Field App Quick Steps available on request There are two types of activation processes Single and Bulk o For single or low count unit activation follow the Single Activation process o For multiple unit activation follow the Bulk Activation process Single Activati...

Страница 13: ...Place your mobile phone on top of the Connect Monitor as depicted until CONNECTING MoXXXXXXXX message is displayed If this process takes longer than 5 seconds try slowly hovering your phone over the device to facilitate alignment of the device NFC module and the phone NFC antenna You may need to hold the phone over the Connect Monitor for a few seconds to establish an NFC connection ...

Страница 14: ...up 5 Upon successful connection you will be prompted with the configuration screen Please specify the Manufacturer Owner and Brand The phone may emit a sound and vibration when NFC is successfully enabled on the Connect Monitor This ensures only authorized connections can be made to the device and data collection is only possible by the assigned Owner It is vital to configure the device to the cor...

Страница 15: ... Connect Field App Available on request Bulk Activation process through SCS Field Open the SCS Field app and follow the steps below 1 From the menu tab navigate to the BULK ACTIVATE MONITORS tab This option is only available for users with the appropriate permissions Please contact the relevant person within your organization User Manager if you wish to gain access to the BULK ACTIVATE MONITORS op...

Страница 16: ...ons Manual FIELD TRIAL PROTOTYPE SAMPLES 16 2 Ready to Scan screen will be displayed From this screen select START BULK ACTIVATION 3 Move your mobile device close to the SCS Monitor you wish to activate message will be visible ...

Страница 17: ...s enabled 6 Continue activation of the next Connect Monitor by repeating Step 4 If this process takes longer than 5 seconds try slowly hovering your phone over the device to facilitate alignment of the device NFC module and the phone NFC antenna You may need to hold the phone over the Connect Monitor for a few seconds to establish an NFC connection The phone may emit a sound and vibration when NFC...

Страница 18: ... Connect Field App WT9404_Set Asset Details through SCS Connect Field App Available on request It is vital to configure the device to the correct Manufacturer and Owner This feature is NOT supported for Bulk Activation in the Field Trial Prototype units So manufacturer and owner needs to be set up at the point of installation This ensures only authorized connections can be made to the device and d...

Страница 19: ...lication installed and activated to the correct database Check for updates in the App Store or Google Play Detailed instructions on how to install and activate Field app can be found in Field App Quick Steps available on request There are three ways the SCS Field app can connect to the Connect Monitor All are accessed through the SELECT COOLER page BLUETOOTH As per an SCS controller select the adv...

Страница 20: ...ne close to the Connect Monitor you wish to connect to If this process takes longer than 5 seconds try slowly hovering your phone over the device to facilitate alignment of the device NFC module and the phone NFC antenna You may need to hold the phone over the Connect Monitor for a few seconds to establish an NFC connection ...

Страница 21: ...Connect Monitor Instructions Manual FIELD TRIAL PROTOTYPE SAMPLES 21 3 The phone will read the NFC tag inside the Connect Monitor and connect to the device over Bluetooth ...

Страница 22: ...ROTOTYPE SAMPLES 22 QR CODE 1 Select BARCODE from the bottom banner 2 Point the camera at the QR code included in the Connect Monitor label FOR FIELD TRIAL UNITS ONLY If the device is already installed the label will be facing the FRONT of the cooler ...

Страница 23: ...Connect Monitor Instructions Manual FIELD TRIAL PROTOTYPE SAMPLES 23 3 The phone will read the QR code and connect to the Connect Monitor over Bluetooth Google Play Apple Store ...

Страница 24: ...hich an alarm is triggered The measured temperature must exceed this setpoint for a time specified by Temperature Out Of Spec Alarm Delay before the alarm is triggered 40 0 to 15 0 or disabled 0 1 C disabled TEMPERATURE OUT OF SPEC ALARM DELAY not supported in Field Trial Prototype units Description Parameter Range Increment Units Default The amount of time the measured temperature must be continu...

Страница 25: ...e cabinet used by the equipment control system This parameter is intended to be set automatically by the Field app upon selection of equipment model 10 0 to 10 0 C 0 1 C 0 0 C TEMPERATURE CALIBRATION OFFSET read write permissions for service technician read only for sales LOGGING INTERVAL Description Parameter Range Increment Units Default Sets the time in minutes between logging of statistics Sta...

Страница 26: ...sing Bluetooth and fully configured but does not have an active Bluetooth connection Normal operation incomplete configuration Two 5 ms flashes every 30 seconds rate configurable Monitor is advertising Bluetooth but with incomplete configuration such as missing asset number or owner ID Bluetooth connected One 5 ms flash every 2 seconds Indicates Monitor has an active Bluetooth connection with a de...

Страница 27: ...NNECTIVITY Bluetooth Capability Bluetooth SMART NFC Capability Passive read write Supported Windows O S for GUI module Windows 7 Windows 8 Windows 8 1 Window 10 Supported Mobile App Devices Android with Bluetooth 4 0 and OS 4 4 3 or above iPhone 4S or later iPAD 3rd Gen or later iPAD mini PHYSICAL Dimensions Connect Monitor Overall Dimensions 107mm H x 42mm W x 27mm D 4 2 H x 1 6 W x 1 1 D Weight ...

Страница 28: ...ation Authorisation and Restriction of Chemicals REACH Regulation EC No 1907 2006 Bluetooth SIG BQB QDL Article 11 Recovery and Recycling Calculation of Theoretical Recovery and Recycling Rate Under nominal operating conditions Approvals pending FCC Declaration CLASS B DEVICE This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may n...

Страница 29: ...equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help RSS Gen RSS 247 statement This device complies with Industry Canada licence exempt RSS standard s Operation is subject to the following two conditions 1 This device may not cause interference and 2 This dev...

Страница 30: ...ng EU Directive 2011 65 EU RoHS The EU Directive which governs the Restriction of Hazardous Substances RoHS in goods This directive is closely linked with the Waste Electrical and Electronic Equipment directive WEEE EU Directive 2012 19 EU WEEE The Waste Electrical and Electronic Equipment directive WEEE which governs the collection recycling and disposal of electrical and electronic goods This di...

Страница 31: ...sors are devices which generate a signal used to control devices as a result of a detected environmental change Probes are a kind of sensor and the two terms are often used interchangeably Thermostat A switch or signal device activated by changes in temperature UL Mark The UL Mark signifies that the product conforms to the relevant safety compliance standard published by Underwriters Laboratories ...