9
© Well Straler all rights reserved
3.3
Safety instructions
Use the appliance solely for heating, and not for other purposes.
Do not ignite the appliance until it is fully installed.
Have the installation and the annual maintenance done by a skilled professional or by
a maintenance company specialising in gas fireplaces.
Only use the original Well Straler terminals. Our appliances are approved for use with
these terminals and can therefore not be used with other terminals.
All elements of the air supply and the gas flue must have at least 25 mm of overlap
when fitted together and be fastened with clamps or stainless steel Parker screws so they
do not slide apart.
Arrange the burner decoration exactly as per the directions.
Do not put flammable substances on the burner decoration.
Keep the area around the pilot flame clear, and do not put any burner decoration
close to the pilot flame.
The pilot flame is the safety mechanism and fuse of the appliance. Wait at least five
minutes to relight the pilot flame if the pilot flame has gone out.
Never operate the appliance without the window.
Ensure the window is correctly fitted.
Replace a broken or cracked pane before reusing the appliance.
Do not make any changes to the appliance.
Only clean the appliance on the outside. Never use abrasive or corrosive cleaning
agents.
Close the gas tap and notify your installer if the unit has made a banging or popping
noise when igniting, or if it does not ignite properly.
Shut off the gas supply and contact your installer in the event of problems and/or if
the appliance is operating poorly.