8
Annual maintenance
Maintenance is limited to cleaning the external housing and the combustion chamber.
◼
Remove the external housing and clean the dust from the combustion chamber
using a damp cloth. Only do this when the appliance is completely cool
◼
Clean the chimney annually, especially if coal or oil heaters have been used
◼
Have a professional perform annual maintenance to ensure the proper functioning
of the appliance.
Always close the gas shutoff valve during maintenance work.
Annual maintenance covers:
◼
Checking that the point of the thermocouple is not burnt
◼
Checking that the main injector or pilot injector are not clogged
◼
Checking the piezo-ignition and the spark plug
◼
Cleaning the burner and blowing out the burner using compressed air
◼
Cleaning the pilot flame (blowing out via the air vents at the bottom)
◼
Checking the operation of the appliance:
▪
The ignition of the pilot flame
▪
Checking for the good adjustment of the pilot flame
▪
Checking the ignition of the main burner;
this must be quick and silent
▪
Checking the operation of the thermostat
◼
Checking the supply and flue gas channels
◼
Removing the build-up on the inside of the window with a damp cloth or a non-
abrasive cleaning agent.
Each gas contains additives in order to detect gas in the event of leakage. These
additives leave a white deposit in the appliance upon burning and thus the glass
should be regularly cleaned. The speed of contamination by this additive depends
on the humidity and the stack effect
◼
Replace a broken or cracked window.
Use only original Well Straler parts.
Always check the gastightness after repairs or maintenance.