49
eikon e1s
Service and repair guide
Electrical installation requirements
Safety rules
Observe the following rules to prevent hazards caused by faulty electrical connections:
•
Only electricians qualified under the terms of EN 50110-1 and from an authorized service company are permitted
to perform work on electrical equipment.
•
The electrical supply must be connected in accordance with applicable local regulations of the professional
associations and of the relevant power supply company.
•
The case of the appliance must be grounded in a suitable manner and connected to an equipotential bonding
system.
•
If two microwave combination ovens are installed in a stacking kit, both cases of the appliances and the stacking kit
itself must be grounded in a suitable manner and connected to an equipotential bonding system.
•
Wear the personal protective equipment as specified in the
Section 1F
.
Grounding instructions
The appliance must be grounded. Connect only to a properly grounded outlet.
See ‘Grounding instructions’ in
Section 1F.
Equipment provided by customer and electrical installation regulations
Table 2.1 shows what equipment must be provided by the customer and what regulations must be observed when
connecting the appliance.
Equipment
Regulations
Fuse
Fuse protection and connection of the appliance must comply with local regulations and
national installation requirements.
Equipotential bonding
The appliance must be incorporated in an equipotential bonding system.
Equipotential bonding: electrical connection that ensures that the frames of electrical
equipment and any external conductive components are at an equal (or practically equal)
potential.
Residual-current device
(RCD)
The installation regulations require protection by a residual-current device (RCD). Suitable
residual-current devices meeting the relevant national regulations must be used.
If the installation includes more than one appliance, one residual-current device must be
provided for each appliance.
Disconnection device
An easily accessible all-pole disconnection device with a minimum contact separation of 3mm
must be installed close to the appliance. The appliance must be connected via this
disconnection device. The disconnection device is used to disconnect the appliance from the
electrical supply for cleaning, repair and installation work.
Table 2.1: Electrical equipment and regulations
The requirements and specifications for e1s
Fitted frequency converter
•
The appliance is fitted with one frequency converter (FC) and an EMC mains input filter.
•
These devices may result in a leakage current of more than 3.5mA per FC drive.
•
Use a suitable RCD for the rated voltage.
Properties of the residual-current device
The residual-current device (RCD) must have the following properties:
•
Filter for filtering out RF currents.
Содержание Merrychef eikon e1s
Страница 11: ...11 eikon e1s Service and repair guide Section 1 Safety ...
Страница 43: ...43 eikon e1s Service and repair guide Section 2 Operations and Installation ...
Страница 82: ...82 eikon e1s Service and repair guide Section 3 Service and Repair ...
Страница 147: ...147 eikon e1s Service and Repair Guide Circuit diagrams ...