3 of 6
Document Number: MSC-017 4/20
Subject: Restoring Ice Machine to Service Procedures
Remove Ice damper(s)
when used. (Dual
Evaporators have two).
Disengage the front and rear
pins of the left damper and
right damper.
10. DUAL EVAPORATORS
ONLY: Remove the
water trough shield.
Grasp the water trough
shield in the center and the
left end.
Flex the water trough shield
in the center and pull the
left end forward until clear
of the side wall. Repeat for
the right end.
Pull water trough shield
forward to remove.
11. Remove the water
pump and water level
probe assembly.
The water pump and water
level probe are removed
from the front right side
of the machine. Pull up on
the water pump and water
level probe assembly to
disengage.
The water pump and water
level probe can be descaled
and sanitized at this point
without complete removal.
If complete removal is
desired, disconnect at the
molex connectors.
12. Remove water trough.
Once the water pump
and water level probe are
removed (step 11); slide the
water trough forward-out of
the ice machine.
13. Remove the ice
thickness probe(s)
(Dual Evaporator have
two).
Compress the hinge pin on
the top of the ice thickness
probe.
Pivot the ice thickness probe
to disengage one pin then
the other.
The ice thickness probe
can be cleaned at this point
without complete removal.
If complete removal is
desired, disconnect the ice
thickness control wiring
from the control board.
14. Remove the water
distribution tube(s)
(Dual Evaporator have
two).
Loosen the two outer
screws (do not remove
screws completely; they
are retained to prevent
loss). Pull forward on the
distribution tube to release
from slip joint. Remove the
water distribution tube.
Disassemble the distribution
tube by loosening the two
(2) middle thumbscrews and
dividing the distribution
tube into two pieces.
Remove both water
distribution tubes on 48”
and dual evaporator models.