Welbilt Manitowoc Indigo NXT Series Скачать руководство пользователя страница 1

Restoring Ice Machine  
to Service

Subject: Indigo NXT Ice Machines

AIR-COOLED, WATER-COOLED, REMOTE AIR-COOLED & 

QUIETQUBE ICE MACHINES

 

1 of 6

 

Document Number: MSC-017  4/20

MANITOWOC  ICE MACHINE DIVISION 

2110 SOUTH 26TH STREET, MANITOWOC, WI 54220

844-724-CARE 

WWW.MANITOWOCICE.COM

RESTORING TO SERVICE PROCEDURES

1.  Remove front panel.

Use a Phillips screwdriver to 

loosen the screw(s) securing 

the door. Do not remove 

screw(s) completely; they 

are secured to prevent loss.

2.  Make sure ice machine 

off.

Turn the ice  machine OFF 

by pressing the power 

button.

3.  Disconnect main 

power at the service 

disconnect  or  breaker.    

n

WARNING

Do not begin cleaning 

other parts of the ice 

machine until line voltage is 

disconnected from the ice 

machine and if applicable 

dispenser.

4.  Empty ice bin, if not 

already empty.

Use an ice scoop to remove 

all ice from the storage bin 

or dispenser.

5.  Remove top cover and 

evaporator dust cover 

(when used).

Lift top cover to remove, 

then lift and remove 

evaporator dust cover.

6.  Remove water curtain 

or splash shield.

Remove water curtain

Gently flex the curtain in the 

center and remove it from 

the right side.  

Slide the left pin out.

Manitowoc recommends a Factory Authorized Service company or Distributor Authorized Service Dealer perform 

thorough preventative maintenance prior to restoring service of the Manitowoc ice machine, storage bin or 

dispenser.  Section 4 (Maintenance) of the Installation, Operation and Maintenance manual should be followed to 

ensure proper cleaning and sanitizing steps are completed.  

Water system components including the water inlet valve, water pump and dump valve may require removal for 

inspection or replacement depending on the potable water quality and the length of time the components had no 

use.  Water cooled ice machines may require the condenser be cleaned and the refrigeration water regulating valve 

evaluated for proper performance.  Air-cooled condensers should be cleaned. This is also a good time to replace 

water filtration, replenish AuCS chemical and replace the Luminice bulb if these Manitowoc accessories are used.