5.2 Adjacent systems
Dealing with the discharged air
During operation, the combi oven generates heat and moisture, which mainly escape upwards into the
surrounding air as hot vapour from the air vent. It is not permitted to connect air ventilation pipes di‐
rectly to the air vent of the combi oven.
The manufacturer recommends using a fume extractor hood or ceiling-fitted ventilation equipment to
extract the discharged air from the room in which the combi oven is operating.
In order to avoid the risk of fire or other damage to the building such as corrosion, mould growth
and/or reduced stability, there must be a sufficiently large distance between the top of the appliance
and the ceiling. This distance depends on the following factors:
■
For guidance on the minimum vertical clearance, see 'Requirements for the installation location' on
■
Type of air-vent system
■
the nature of the ceiling in the installation location
It is a fundamental requirement that the combi oven is always set up, installed and operated in accord‐
ance with national and local standards and regulations (in the latest version).
In addition, please observe the following regulations:
■
VDI Directive 2052 'Ventilation equipment for kitchens'
■
Guidance from the local building authority for fume extraction systems
5 Setting up the appliance
Installation manual
43