13.
PREVENTATIVE MAINTENANCE
FOR MAINTENANCE AND REPAIRS CONTACT YOUR AUTHORIZED MANITOWOC SERVICE AGENCY
AND HAVE A QUALIFIED SERVICE TECHNICIAN MAINTAIN YOUR EQUIPMENT.
If for any reason this unit is not
functioning correctly DO NOT
OPERATE. Contact your
authorized service agent.
WARNING:
!
0
DAILY
PRE-STARTUP
INSPECTION
1.
Flue (A) is not obstructed.
2.
Product Discharge Valve (B) and opens and
closes.
4.
Bridge (C) lifts up and screen is in place.
5.
Pressure Gauge (D) is in the green when unit is
cold.
6.
Green Light (E) comes on when unit is energized.
7.
Red Light (F) comes on when unit is tilted).
8.
All switches are functioning correctly.
SIX MONTH SERVICE INSPECTION
1. Perform daily startup inspection.
2. Gasket (G) around top cover is in good condition.
3. Tilt hand (H) wheel is tight.
4. Grease bearings on both trunnions.
5. Check for play in gears (adjust if required).
6. Fasteners securing panels are in place and tight.
7. Perform pressure relief valve periodic test
(see Pressure Relief Valve Testing).
8. Adequate exhaust and makeup air is supplied to working area.
9. Check for hydraulic leaks.
10. Check safety systems have not been bypassed.
YEARLY SERVICE INSPECTION
1. Perform six month service inspection.
2. Check kettle maximum temperature setting (see Calibrating Procedure).
3. Inspect safety thermostat for proper connections (see Safety Thermostat).
4. Inspect Low water probe for proper connections (see Low Water Level Probe).
5. Inspect safety valve installation (see SAFETY VALVE INSTALLATION).
6. Clean blower.
7. Perform free air calculation (see FREE AIR CALCULATION).
8. Replace hydralic oil and filter.