![Welbilt C4 EB 12.20 Скачать руководство пользователя страница 84](http://html.mh-extra.com/html/welbilt/c4-eb-12-20/c4-eb-12-20_installation-manual_953843084.webp)
9.8 Electrical supply, marine
C4 EB (three-phase FC)
12.20
20.10
20.20
3~ 440V 50/60Hz
Rated power consumption
[kW]
28.2
32.6
56.3
Convection power
[kW]
27.8
31.8
55.5
Steam power
[kW]
26.3
26.3
33.6
Motor power
[kW]
0.35
0.7
0.7
Rated current
[A]
37.0
42.8
73.9
Fuse rating
[A]
50
50
100
Residual current
[mA]
-
-
-
Protective earth current
[mA]
-
-
-
Recommended conductor cross-section for wires laid uncovered in air up to 5 m in
length.
[mm
2
]
4G16
4G16
4G35
Residual-current device
Type
B
B
B
3~ 480V 50/60Hz
Rated power consumption
[kW]
33.4
38.6
66.8
Convection power
[kW]
33.0
37.8
66.1
Steam power
[kW]
31.3
31.3
39.9
Motor power
[kW]
0.35
0.7
0.7
Rated current
[A]
40.3
46.5
80.5
Fuse rating
[A]
50
50
100
Residual current
[mA]
-
-
-
Protective earth current
[mA]
-
-
-
Recommended conductor cross-section for wires laid uncovered in air up to 5 m in
length.
[mm
2
]
4G16
4G16
4G35
Residual-current device
Type
B
B
B
C4 ES (three-phase FC)
12.20
20.10
20.20
3~ 440V 50/60Hz
Rated power consumption
[kW]
28.2
32.6
56.3
Convection power
[kW]
27.8
31.8
55.5
Motor power
[kW]
0.35
0.7
0.7
Rated current
[A]
37.0
42.8
73.9
Fuse rating
[A]
50
50
100
Residual current
[mA]
-
-
-
Protective earth current
[mA]
-
-
-
Recommended conductor cross-section for wires laid uncovered in air up to 5 m in
length.
[mm
2
]
4G16
4G16
4G35
Residual-current device
Type
B
B
B
3~ 480V 50/60Hz
Rated power consumption
[kW]
33.4
38.6
66.8
Convection power
[kW]
33.0
37.8
66.1
Motor power
[kW]
0.35
0.7
0.7
9 Technical data