9.3 Electrical supply, EB/ES
C4 EB (three-phase FC)
12.20
20.10
20.20
3~ 400V 50/60Hz
Rated power consumption
[kW]
33.7
38.9
67.3
Convection power
[kW]
33.3
38.1
66.5
Steam power
[kW]
31.6
31.6
40.2
Motor power
[kW]
0.35
0.7
0.7
Rated current
[A]
48.7
56.2
97.3
Fuse rating
[A]
50
63
100
Residual current
[mA]
-
-
-
Protective earth current
[mA]
-
-
-
Recommended conductor cross-section for wires laid uncovered in air up to 5 m in
length.
[mm
2
]
5G16
5G16
5G35
Residual-current device
Type
B
B
B
C4 ES (three-phase FC)
12.20
20.10
20.20
3~ 400V 50/60Hz
Rated power consumption
[kW]
33.7
38.9
67.3
Convection power
[kW]
33.3
38.1
66.5
Motor power
[kW]
0.35
0.7
0.7
Rated current
[A]
48.7
56.2
97.3
Fuse rating
[A]
50
63
100
Residual current
[mA]
-
-
-
Protective earth current
[mA]
-
-
-
Recommended conductor cross-section for wires laid uncovered in air up to 5 m in
length.
[mm
2
]
5G16
5G16
5G35
Residual-current device
Type
B
B
B
C4 EB (single-phase FC)
12.20
20.10
20.20
3N~ 400V 50/60Hz (3/N/PE)
Rated power consumption
[kW]
33.7
38.9
67.3
Convection power
[kW]
33.3
38.1
66.5
Steam power
[kW]
31.6
31.6
40.2
Motor power
[kW]
0.35
0.7
0.7
Rated current
[A]
48.7
56.2
97.3
Fuse rating
[A]
50
63
100
Residual current
[mA]
~7.5
~16.5
~16.5
Protective earth current
[mA]
~7.5
~16.5
~16.5
Recommended conductor cross-section for wires laid uncovered in air up to 5 m in
length.
[mm
2
]
5G16
5G16
5G35
Residual-current device
Type
A/B
A/B
A/B
9 Technical data
Installation manual
77
Содержание C4 EB 12.20
Страница 2: ......
Страница 5: ...10 9 Convotherm 4 20 20 injection gas appliance 117 Table of Contents Installation manual 5 ...