9.7 Electrical supply, Mexico/Nicaragua
C4 GB (single-phase FC)
12.20
20.10
20.20
1N~ 120V 60Hz
Rated power consumption
[kW]
0.6
1.1
1.1
Convection power
[kW]
0.1
0.2
0.2
Steam power
[kW]
0.1
0.1
0.1
Motor power
[kW]
0.4
0.7
0.7
Rated current
[A]
5.7
9.9
9.9
Fuse rating
[A]
16
16
16
Residual current
[mA]
-
-
-
Protective earth current
[mA]
-
-
-
Recommended conductor cross-section for wires laid uncovered in air up
to 5 m in length.
[mm
2
]
3G2.5
3G2.5
3G2.5
Residual-current device
Type
A/B
A/B
A/B
2~ 230 V 50/60Hz
Rated power consumption
[kW]
0.6
1.1
1.1
Convection power
[kW]
0.1
0.2
0.2
Steam power
[kW]
0.1
0.1
0.1
Motor power
[kW]
0.35
0.7
0.7
Rated current
[A]
2.7
4.7
4.7
Fuse rating
[A]
16
16
16
Residual current
[mA]
11.5
-
-
Protective earth current
[mA]
-
-
-
Recommended conductor cross-section for wires laid uncovered in air up
to 5 m in length.
[mm
2
]
3G2.5
3G2.5
3G2.5
Residual-current device
Type
A/B
A/B
A/B
C4 GS (single-phase FC)
12.20
20.10
20.20
1N~ 120V 60Hz
Rated power consumption
[kW]
0.5
1.0
1.0
Convection power
[kW]
0.1
0.2
0.2
Motor power
[kW]
0.4
0.7
0.7
Rated current
[A]
4.7
8.9
8.9
Fuse rating
[A]
16
16
16
Residual current
[mA]
-
7.5
-
Protective earth current
[mA]
-
-
-
Recommended conductor cross-section for wires laid uncovered in air up
to 5 m in length.
[mm
2
]
3G2.5
3G2.5
3G2.5
Residual-current device
Type
A/B
A/B
A/B
2~ 230 V 50/60Hz
Rated power consumption
[kW]
0.5
1.0
1.0
Convection power
[kW]
0.1
0.2
0.2
Motor power
[kW]
0.35
0.7
0.7