6.1.2 Carrying out the electrical installation
Requirements
Check that the following requirement has been met:
■
The connection point of the appliance is disconnected from the customer power supply and protective measures taken to
ensure the power cannot be switched on again.
Checking the supply ratings and electrical connections
1.
Remove the side panel from the appliance.
The circuit diagram and spare parts list are located in the wiring com-
partment.
2.
Check that the electrical supply ratings on the type plate (see 'Identify-
ing your combi oven' on page 7) match the figures for the building's
power supply and those given in the circuit diagram. It is only permitted
to connect the appliance if all these values tally with each other.
3.
Check all screw connections and terminals on the appliance.
The connections may have worked loose during transport.
Carrying out the electrical installation
The figure below shows a size 12.20 combi oven as an example for all appliance sizes:
1.
Remove the side panel from the appliance.
2.
Connect the appliance to a protective equipotential bonding system at
the designated connection point (3).
3.
Use the mains power cable to connect the power supply to the appli-
ance at the -1X0 terminal block (1).
4.
Make sure that the cable gland (2) is tightened firmly because it also
acts as a cable strain relief.
5.
For C4 ES/GS:
Reset the safety thermostat for the cooking chamber if necessary.
For C4 EB/GB:
Reset the safety thermostats for the cooking chamber and boiler if nec-
essary.
6.
Fit the side panel on the appliance and check that it is fixed correctly in
place.
6 Installation