Disassembly of a TgxV DN250/PN6 valve
The disassembled components must be stored in a clean place. Damage to the
sealing surfaces requires great effort and expenditure to remedy.
Required tools and auxiliary agents
Allen wrench, 14mm
Open-end spanner SW13.
Transport protection device with WEKA-no. 46933
Crane mounting tool (WEKA-no. 2838)
STEP
Picture
Description
Additional note: Depending on the nominal width of the valve, the components may slightly vary in
appearance. However, the steps remain the same.
1
Loosen the screw of the orifice hole using the
open-end spanner SW13
Place the plug onto a clean surface.
Attention
Carefully remove the plug.
The released space may be under
pressure!
2
Loosen all cylinder head screws using an allen
wrench, 14mm
The screws and washers can be removed.
Carefully lift the flange and pull over the upper
part