9
3.2 Terminal connection
Terminal
Function
Level
Comment
Multipoint plug, 32-pin
+
+24V
Supply voltage
3/4/A/B
-
GND (OV)
Supply voltage
1/2/A/B
1
Rotation direction
LOW CW
HIGH CCW
Input 24V
26A
2
Enable
(RESET/Stop)
LOW: - Disable
- Reset Alarm
HIGH: ENABLE
Input 24V
19A
3
Start “edge“
rising edge
Input 24V
18A
4
Automatic
Output 24V/100mA
16B
5
additional stop
Log. “1“ activ
Input 24V
18B
6
Alarm: Position overrun
Output 24V/100mA
10B
7
Alarm: Drive time timeout
Motor overload
Output 24V/100mA
10A
8
Sum of alarms
Output 24V/100mA
9A/B
9
Start permitted
Output 24V/100mA
8B
10
Table in position
Output 24V/100mA
Output 24V/100mA
8A
C
Motor contactor “Forward“
Output 24V/2A
5A/B
D
Brake
Output 24V/2A
6A/B
E
Motor contactor “Backward“
Output 24V/2A
14A/B
F
Limit switch
Log. “1“ activ
Input 24V
15B
G
Release brake
Log. “1“ activ
Input 24V
15A
H
Start “level“
Log. “1“ activ
Input 24V
17B
T
Temperature sensor
Log. “0“ activ
Input 24V
17A