Safety
2.3 Residual hazards
2
The operator is responsible for ensuring that a suitable safety concept is developed and
applied for the safe operation of the machine.
The operator must take all measures to protect his personnel against injury by the
machine.
These include:
•
Safety housing with monitored safety door
•
Emergency stop circuit
•
Light barriers or switch mats
•
Warning indicators
•
Attach danger sign at the access point of the entire machine
We also recommend that the danger signs shown in chapter 2.2 are attached in an
enlarged form at the access points to the protection area of the entire machine.
2.3
Residual hazards
2.3.1
General residual hazards
Danger sign
Meaning
Prohibited for persons with pacemakers
ASR A1.3 Annex 1; DIN 4844-2:2001-02 and DIN 4844-2/A1:2004-05;
ISO/FDIS 7010: 2003; ISO 7010
Strong magnetic fields
The axles give rise to strong magnetic fields. They can lead to failure of medical implants
such as pacemakers and may result in severe or fatal injury. Persons with medical
implants such as pacemakers must maintain a safety distance of at least 50 cm from the
axles.
Objects made of magnetisable materials such as jewellery, watches or tools can be
attracted. Do not wear any magnetisable materials when handling the machine. Handle
tools carefully. Injuries caused by being pulled in.
Missing safety equipment
Operation without safety equipment is dangerous. The realisation of a suitable The
operator is responsible for the safety concept. The operator must provide for sufficient
safety measures such as protective grating, light grids, emergency stop button, covers,
warning notices, etc. Operation without safety equipment is prohibited. Injuries caused by
squeezing, impact, magnetism.
Missing danger signs
Damaged or illegible danger signs no longer fulfil their purpose. Make sure the danger
signs are complete and legible. Replace damaged danger signs.
Risk of explosion during operation in a potentially-explosive environment.
Due to constraints governing the correct used of the machine, the machine is not desi-
gned for use in a potentially-explosive atmospheres. The operator must take all
measures to ensure that the machine is only operated in a correct manner.
Use of spare parts / attachment of supplemental devices
If spare parts are used, or if supplemental devices are attached that are not approved by
the manufacturer, consequential damages can occur. Only use spare parts that are cited
in our spare parts list or spare parts that we have approved. You must consult with us prior
to attaching supplemental devices. Failure to comply with these instructions means that
the possibility of personal injury cannot be excluded.
Danger of crushing injuries due to impermissible changes
Injuries can occur as a consequence of impermissible changes. Do not make any
changes to the machine. Failure to comply with these instructions means that the possi-
bility of personal injury cannot be excluded.