Manual R06-2016
97 / 172
ROTARY INDEXING TABLE CONTROLLER
EF2...B
OPERATION / DESCRIPTION OF WEISS SOFTWARE |
8.3 Machine configuration
I/O configuration terminal module
1. Select terminal module interface.
2. Select interface compatibility.
The following description of the I/O configuration is valid for the interface compatibility standard. For EF1 com-
patibility mode see chapter 8.3.5.2 „EF1 compatible configuration“ on page 98.
3. Click the Next button.
➱
The window for entering the I/O mapping - terminal assignment TM15_DigitalEA is opened.
I/O mapping for the terminal assignment TM15_DigitalEA is done in the same way as the I/O mapping for the
PROFIBUS interface (see chapter „I/O configuration PROFIBUS“ on page 90).
4. Adjust the system time (see chapter „Adjust system time“ on page 93).
5. Restart the controller (see chapter „Restart“ on page 94).
2.
1.
3.
Содержание 3RT2017-1BB42
Страница 1: ...MANUAL ELECTRICAL SYSTEM DOCUMENTATION ROTARY INDEXING TABLE CONTROLER EN_06_2016 EF2 ...
Страница 170: ...Manual R06 2016 170 172 ROTARY INDEXING TABLE CONTROLLER EF2 B APPENDIX 13 5 Personal notes 13 5 Personal notes ...