Installation and operating instruction
Hydraulic unit WWP LS 8 ... 16-B
6 Operation
83306902 2/2017-05 La
42-88
6.7.1.2 Heat pump
Info
Heat pump
Information
Description
Status outdoor
unit
Current operating phase of outdoor unit.
Setpoint com-
pressor frequency
(1
Compressor frequency required by controller.
Actual compressor
frequency
(1
Current compressor frequency on outdoor unit.
Air intake temper-
ature
(1
Current air intake temperature at heat exchanger of outdoor unit.
Air intake sensor (OAT)
Heat exchanger OU
inlet
(1
Current refrigerant temperature, measured at inlet of heat exchanger in outdoor
unit (vaporiser).
Heat exchanger sensor OU inlet (OCT)
Heat exchanger OU
centre
(1
Current temperature in heat exchanger of outdoor unit (vaporiser).
Heat exchanger sensor OU centre (OMT)
Compressed gas
(1
Current refrigerant temperature, measured at outlet of vaporiser in the outdoor unit.
Compressed gas temperature sensor (CTT)
Heat exchanger in-
ternal
(1
Current refrigerant temperature, measured at inlet of heat exchanger of hydraulic
unit (compressed gas).
Internal heat exchanger pressure sensor (B12)
Refrigerant in-
ternal
(1
Current refrigerant temperature, measured at outlet of heat exchanger in indoor
unit (condenser).
Internal refrigerant sensor (B8)
Vaporiser operat-
ing hours
(1
Operating hours of vaporiser since commissioning.
Operating cycles
vaporiser
(1
Number of vaporiser starts since commissioning.
Operating cycles
defrost
(1
Number of defrosts at outdoor unit since commissioning.
Outdoor unit vari-
ation
Type and version of outdoor unit.
(1
Only appears in Expert level.