![Weishaupt WWP LS 10-B R HE Скачать руководство пользователя страница 34](http://html.mh-extra.com/html/weishaupt/wwp-ls-10-b-r-he/wwp-ls-10-b-r-he_installation-and-operating-instruction_953380034.webp)
Installation and operating instruction
Hydraulic unit WWP LS 8 ... 16-B
6 Operation
83306902 2/2017-05 La
34-88
6.4 Favourites level
For fast access, frequently required parameters are permanently stored in the
Favourites level.
Depending on the hydraulics and control variations, certain information and para-
meters are hidden.
Display favourites
Select Favourites level using dial knob and confirm.
Display changes to Favourites level.
System
operating
mode
Room
setpoint
temperature
40.0
Flow temperature
7:37
2017-03-13
Monday
7.0°C
50 °C
Off
Heating operation
°C
Time program
DHW
Push
DHW setpoint
temperature
DHW
program
Parameters
Description
System operating
mode
Determines the operating mode of the entire system.
Room setpoint tem-
perature
Room setpoint temperature for the temperature level selected [ch. 6.4.1].
Comfort
Normal
Setback
The levels can be assigned to specific times of the day using the heating program
[ch. 6.4.3].
Time program
(heating program)
The heating program is used to stipulate the times of the day when comfort, nor-
mal or setback heating is used.
The time program can be adapted individually [ch. 6.4.3].
The heating program is only activated in operating mode:
Heating
DHW Push
DHW Push can be used to cover hot water demand, which differs from the time
program.
The DHW tank is heated to and maintained at normal temperature for the duration
set.
DHW setpoint tem-
perature
DHW setpoint temperature for normal and setbackoperation [ch. 6.4.2].
Normal
Setback
Normal and setback operation can be assigned to specific times of the day using
the DHW program [ch. 6.4.3].
DHW program
The DHW program is used to stipulate the times of the day when the DHW tanks
is heated to normal temperature or setback temperature.
The time program can be adapted individually [ch. 6.4.3].
The DHW program is activated in operating mode:
Heating
Summer
The DHW program is used to stipulate the times of the day when the DHW tanks
is heated to normal temperature or setback temperature.