Installation and operation instructions
Separation station WHI sol/heat 20 #1 / 40 #1; Separation station WHI sol/aqua 20 #1 / 40 #1
2 Safety
83514202
▪
1/2014-06
▪
Ext. PAW
5-36
2
Safety
2.1
Designated use
The station may only be used in solar thermal installations as separation station between
the solar circuit and the heating circuit (in the case of WHI sol/heat) or the potable water
circuit (in the case of WHI sol/aqua), taking into consideration the technical limit values
indicated in this manual. Due to its design, the station may only be installed and
operated as described in this manual!
Use only original accessories in connection with the separation station.
Using the station contrary to its designated use will invalidate all liability claims.
2.2
Safety instructions
The following must be observed during installation and commissioning:
•
Relevant local and national regulations
•
Accident prevention regulations of the employers' liability insurance association
•
Instructions and safety instructions mentioned in these instructions
WARNING
Danger of scalding due to escaping vapour!
With safety valves there is a risk of scalding due to the escape of
vapour.
During installation, check the local conditions and check whether
a discharge line must be connected to the safety group.
Observe the instructions regarding the safety valve.
The pressures for the expansion tank calculated by the
plant designer and the operating pressure of the
installation must be set.
WARNING
Risk to life and limb due to electric shock!
Prior to performing electrical work on the controller,
de-energise the system.
For more information, see enclosed installation and
operation instructions of the station controller.
Do not connect the controller to the mains until all
installation work, flushing and filling have been
completed.
This avoids an unintentional start of the motors.
The plug-in pump lines are permanently supplied with a
mains voltage of 230 V and cannot be switched off via
the controller.
CAUTION
Risk of burns!
The valves and fittings and the pumps can become heated up to
more than 100 °C during operation.
The insulation shell must remain closed during
operation.