Installation and operating instruction
Gas burner WG40…/1-A ZM-LN
7 Commissioning
83300002 1/2019-02 La
50-128
7.2 Adjusting the burner
7.2.1 Burner without variable speed drive
DANGER
Risk of electric shock
Touching the ignition device can lead to electric shock.
Do not touch ignition device during the ignition process.
Check flame signal during commissioning [ch. 7.1.1].
1. Preset combustion manager
Unplug bridging plug No. 7 on combustion manager.
Switch on voltage supply.
Combustion manager drives to Standby.
Press [G] and [L/A] keys simultaneously.
Combustion manager changes to access level.
Press [+] key.
Combustion manager changes into the setting level for step points.
Press [+] key.
Factory setting operating point P
9
(full load) is displayed.
Press and hold [L/A] key and set air damper setting determined using the [–] or
[+] key [ch. 7.1.6].
Press and hold [G] key using [–] or [+] key set gas butterfly valve to the same
value.
Press [+] key.
Factory setting operating point P
1
(partial load) is displayed.