MT-600/8000 series 

 

MT-615X / MT-8150X 

 

Installation Instruction 

 

1.0 Installation and Startup Guide   

Install Environment 

 

Where  
Used

 

The MT-600/8000 Series is designed for industrial. The temperature range of operating 
is from 32 to 113 °F (0 to 45 °C) , as majority of industrial environments. It may not 
be suitable for using in certain outdoor applications. Please consult the factory for 
advised usage in outdoor applications. 

NEMA 
Rating 
 

The MT-600/8000 Series front bezel is NEMA 4 rated. When installed properly in a 
NEMA 4 panel, the NEMA 4 rating of the panel will not be compromised. This means 
that fluids will not enter the panel during wash downs. 

Electrical 
Environment 

The MT-600/8000 Series has been tested to conform to European CE requirements. 
This means that the circuitry is designed to resist the effects of electrical noise. This 
does not guarantee noise immunity in severe cases.    Proper wire routing and 
grounding will insure proper operation. 

Mechanical 
Environment 

 
 
 
 

Avoid installing units in environments where severe mechanical vibration or shocks 
are present. 

2.0 Installation Instructions 

2.1 Mounting Instructions 

 

2.1.1 Location Considerations 

 

Care should be taken when locating equipment behind the unit to ensure that AC power wiring, PLC 

output modules, contactors, starters and relays, and any other source of electrical interference are located 
away from the back of the unit. 

 
 
Particular note should be taken to the position of variable speed drives and switching power supplies. 

Their input and load cables should be screened to a central star earth point. 

Содержание MT-615 Series

Страница 1: ...Series has been tested to conform to European CE requirements This means that the circuitry is designed to resist the effects of electrical noise This does not guarantee noise immunity in severe case...

Страница 2: ...esent This will cause condensation of water in the device z Do not install these terminals in environments where have inflammable gases 2 2 Power Connections Make sure that all local and national elec...

Страница 3: ...t always be large enough to carry the maximum short circuit current of the path being considered Ground conductors should be connected to a tree from a central star earth ground point This ensures tha...

Страница 4: ...nadvertent errors that might be introduced if programs are changed while the equipment is in operation z The ICS 3 304 81 Safety Recommendations are reproduced by permission of the National Electrical...

Страница 5: ...S485 2w Com1 RS485 4w Com3 RS485 Com3 RS232 1 Rx Data Rx 2 Rx Data Rx 3 Tx Tx 4 Tx Tx 5 GND Signal Ground 6 Data Data 7 TxD Transmit 8 RxD Receive 9 Data Data The Com1 RS232 RS485 2wire 4wire Com3 RS2...

Страница 6: ...tives that apply to the MT 600 8000 Series z EMC Directive 2004 108 EC electromagnetic emissions and immunity z UL508 ISBN 0 7629 0404 6 machine safety z MT600 products will be CE marked to indicate c...

Страница 7: ...TC Built in CR2032 3V lithium battery General Specification Input Power 24 10 VDC 21 6 26 4VDC Power Consumption 1 6 A 24VDC Isolated Power Supply Built in CE FCC Complies with EN 55022 1998 A1 2000 A...

Страница 8: ...COM1 RS485 2 4W COM3 RS485 COM3 RS232 COM1 RS232 COM2 RS232 m j a IDE interface DOM slot h Line Out b Mini USB i USB Host port x 2 c Fuse j Ethernet port 10 100 Base T d Power connector k Com1 RS485...

Отзывы: