Specialized Concentrated Focused
「
34
」
Operation
100
110
120
130
140
150
90
80
70
60
50
%
Fig. 3-17 Spindle Override Selection Switch
The least unit of ruler of spindle override is 10% (10% for each scale), and the setting range of spindle
override is
“50% ~ 150%”.
3.5.2 Parameter Specification
Related Parameters
Parameter
Definition
Setting Range
Max spindle speed
The max. allowable rotation speed of spindle (matched
with the setting value of converter)
0~60000 r/min
CenterSpindlerev
It specifies the spindle speed if spindle is enabled in
centering. The value should be consistent with inverter
setting.
0~24000 r/min
The value of ”Spindle speed” must be less than that of parameter “Max spindle speed”; the max.
setting value of rotary speed of N1054 is corresponding to analog SVC 10V; when the converter
reaches the max. voltage 10V, the corresponding rotary speed of converter is the value of
parameter
“Max spindle speed”.
Spindle SettingSpeed
Re al time Voltage of AnalogSVC
10V Spindle Override
Max.Spindle Speed
Related Parameters
Parameter
Definition
Setting Range
Stop spindle while
pausing
Whether to stop spindle automatically when machining
pauses
True: Stop
False: Not stop
Stop spindle while
stopping
Whether to stop spindle automatically when machining
finishes
True: Stop
False: Not stop
Is open coolant
while starting
Whether to open coolant at start
True: Open
False: Not open
Is close coolant
while stopping
Whether to close coolant at end
True: Close
False: Not close
Spindle start/stop
time
It is used to set the delay time for waiting spindle speed
reaching the maximum value or zero.
0~60000 ms
Parameter
“Spindle start/stop time “ sets the delay time of spindle on/ off, because a certain time is
needed before spindle reaches the rated rotary speed since start-up or stops until reaching zero