61
2. In the
Param
window, click the
Operator
pull-down menu in the left column and
select
Manufacturer
.
3. Set the following parameters:
o
Encoder Direction
: Indicates the direction of the axis encoders. 1: positive
direction; -1: negative direction
o
Encoder digits
: Indicates the digit number of the servo motor encoder.
Value range: 10
–29.
o
Electronic gear ratio(numerator)/Electronic gear ratio(denominator)
:
Indicates whether the servo drive enlarges or shrinks the received pulse
frequency from the upper computer. If the
Electronic gear
ratio(numerator)/Electronic gear ratio(denominator)
value is larger than 1,
the servo drive enlarges the pulse frequency. If the
Electronic gear
ratio(numerator)/Electronic gear ratio(denominator)
value is smaller than
1, the servo drive shrinks the pulse frequency.
o
Pitch
: The movement or rotation angle of the feed axis per lead screw turn.
3.5 Check Axis Direction
Determine the positive direction for the machine axes based on the right-hand rule and
check to see if the axis directions are correct to avoid possible damage.
Taking the X axis as an example, follow the steps below to check the axis direction:
1. Determine the X axis positive direction based on the right-hand rule.
2. In the menu bar, go to
System
>
Global Parameters
.