EX35A Terminal Board Instruction 

Version: 2019.5 1st Version 

Author: Document Department 

Weihong Corporation, All Rights Reserved 

Dear customers, 

Please carefully read this instruction manual before you install the terminal board 
and set up the CNC system. For more product information, find at 

WEIHONG 

Documentation

1

 

Safety Precautions 

Before using the terminal board, please pay much attention to the following: 

 

This terminal board is used for extending output ports. Do not touch any 

internal circuit or components when you power up the terminal board. 

 

Internal circuit of the terminal board consists of CMOS IC that can be destroyed 

by static electricity. Therefore, do not touch any circuit board before you take 

any preventive actions. 

 

The terminal board is a type of fine instruments. Do not discharge any 

components by yourself. 

 

Make sure surrounding environment is safe and clean, to avoid any possible 

damage from iron dust, wire, water, corrosive gas, or corrosive liquid. 

 

Ambient temperature: -40°C~85°C; Ambient humidity: 0%~90%, no freezing 
and condensation. 

 

The terminal board must be safely grounded, to avoid thunder shock or 
electrical leak. 

 

Space of over 50mm in each side must be secured to ensure good ventilation or 
heat dissipation. Recommended operating temperature: 0°C~55°C. 

 

Rated power for the terminal board should be within range of 24V±10%. Use a 

power regulator in case of instable power supply. 

 

Before connecting or disconnecting with the terminal board, make sure the 

power is off, to avoid electrical shock to the personnel or damage to the 

terminal board. 

Содержание EX35A

Страница 1: ...tricity Therefore do not touch any circuit board before you take any preventive actions The terminal board is a type of fine instruments Do not discharge any components by yourself Make sure surrounding environment is safe and clean to avoid any possible damage from iron dust wire water corrosive gas or corrosive liquid Ambient temperature 40 C 85 C Ambient humidity 0 90 no freezing and condensati...

Страница 2: ... a extension board for Lambda series terminal boards It adopts modular design in appearance which makes it easy to install It has the following features Supports two groups of interfaces for 24V power supply Group A 24V_A COM_A Group B 24V_B COM_B Supports 32 output ports at most For each output supports 24V 3A in voltage current Supports cascading connection of other extension boards 3 Terminal D...

Страница 3: ...5 Power supply 24V_B 24V input supplying power for Y16 Y31 terminals If Y16 Y31 terminals are not used it can be disconnected with the power supply Two terminals for 24V_B internal positive two for COM_B internal negative 6 Communication interface Connects to the upper controller 4 System Running Indicator See the following for flashing frequency of SYSTEM LED indicator in the terminal board by wh...

Страница 4: ...上海维宏电子科技股份有限公司 SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 4 5 5 Dimensions Front view unit mm Side view unit mm ...

Страница 5: ...n stability Length of the earthing cable should depend on technical requirements of the electrical device Generally the shorter the better The earthing cable for the terminal board must be separate with earthing cables for device with high current load for example electric welding machine or motor In case that 24V DC power only supplies power for one 24V_A maximum output current for Y00 Y15 is 15A...

Страница 6: ...Shanghai Weihong Electronic Technology Co Ltd Address No 1590 Huhang Rd Fengxian Shanghai China 201401 Hot line 400 882 9188 Website www weihong com cn en SPECIALIZED CONCENTRATED FOCUSED ...

Отзывы: