![Weidmüller IE-SW-L3-SL28M Скачать руководство пользователя страница 229](http://html1.mh-extra.com/html/weidmuller/ie-sw-l3-sl28m/ie-sw-l3-sl28m_manual_952378229.webp)
User Manual Managed Switches
227
B. Modbus Register Table
Registers can be read via ID = 1 and function code 4 (Input register).
Tag name
Register
address
(HEX)
Register
address
(DEC)
Data Type
Max Data
Length
(Words)
Setting (Description)
System Information
Vendor
0x0000
0
Word
1
0x6574
Unit ID
0x0001
1
Word
1
Unit ID (Ethernet = 1)
Product Code
0x0002
2
Word
1
The last code of the OID
Switch Port
Number
0x0008
8
Word
1
Vendor Name
0x0010
16
String
16
Product Name
0x0030
48
String
16
Version
0x0051
81
Word
2
Firmware v Kernel
version
Firmware Release
Date
0x0053
83
Word
2
Firmware was released on
2007-05-
06 at 09 o’clock
Word 0 = 0 x 0609
Word 1 = 0 x 0705
MAC Address
0x0055
85
Word
3
Eg. 0x001e 0x9412 0x2233
Power 1
0x0058
88
Word
1
0x0000: Off
0x0001: On
Power 2
0x0059
89
Word
1
0x0000: Off
0x0001: On
Fault LED Status
0x005a
90
Word
1
0x0000: Off
0x0001: On
IP Address
0x0090
144
String
16
Eg. 192.168.1.110
System Name
0x0100
256
String
128
System
Description
0x0200
512
String
128
System Location
0x0300
768
String
128
System Contact
0x0400
1024
String
128
Port Information
Port 1 to 6 Status 0x1000 to
0x1005
4096
Word
1
0x0000: Link down
0x0001: Link up
0x0002: Disable
Port 1 to 6 Speed 0x1100 to
0x1105
4352
Word
1
0x0000: 10M-Half
0x0001: 10M-Full
0x0002: 100M-Half
0x0003: 100M-Full
Port 1 to 6 Flow
Ctrl
0x1200 to
0x1205
4608
Word
1
0x0000:Off
0x0001:On
Port Description
0x1400 to
0x1405
5120
String
16
Eg. 100TX
Port PoE Voltage 0x1800~ 6144
Word
1
Eg. 0x0005: PoE voltage =
5V
Port PoE Current 0x1830~ 6192
Word
1
Eg. 0x000D: PoE current =
13A
Port PoE Power
0x1860~ 6240
Word
1
Eg. 0x000A: PoE power =
10W