background image

 
 
 
 
 
 
 

FreeCon Active 

PROFINET POF Media Converter

 

IE-CDM-V14MRJSCP/VAPM-C 

132444000 

 

Hardware Installation Guide 

 

 
 
 
 
 

   

 
 
 

Second Edition, August 2018 

Doc no. 1346050000 (02) 

 
 
 
 
 
 
 

Copyright Notice 

Copyright 

 2018 Weidmüller Interface GmbH & Co. KG 

All rights reserved. 

Reproduction without permission is prohibited. 

 
 

 

Содержание IE-CDM-V14MRJSCP/VAPM-C

Страница 1: ...er IE CDM V14MRJSCP VAPM C 132444000 Hardware Installation Guide Second Edition August 2018 Doc no 1346050000 02 Copyright Notice Copyright 2018 Weidmüller Interface GmbH Co KG All rights reserved Reproduction without permission is prohibited ...

Страница 2: ...shipped with the following items If any of these items are missing or damaged please contact your Weidmüller customer service for assistance FreeCon Active device Hardware Installation Guide This document Features PROFINET IRT Repeater with diagnostic functions PROFINET Power Push Pull connector PROFINET Data PushPull connector with POF and RJ45 Temperature range from 20 to 55 C Input voltage from...

Страница 3: ...nsions unit mm Wall Mounting Mounting the FreeCon Active on the wall requires 4 screws Use the FreeCon Active device as a guide to mark the correct locations of the 4 screws We recommend M4x10mm or longer torque 2 5 Nm ...

Страница 4: ...E Do not run signal or communications wiring and power wiring in the same wire conduit To avoid interference wires with different signal characteristics should be routed separately It is strongly advised that you label wiring to all devices in the system when necessary Pin Assignement 1 L1 24 VDC US1 2 N1 0 VDC US1 3 L2 24 VDC US2 4 N2 0 VDC US2 5 FE Functional earth Use power plug 2465440000 IE P...

Страница 5: ...d causing serious damage to your eyes do not stare directly into the Laser Beam Use PushPull data plug 1 1191550000 IE PS V14M 2SC POF 2 1012170000 IE PS V14M RJ45 FH P 1 2 LED Indicators The front panel of the Ethernet Switch contains several LED indicators The function of each LED is described in the table below LED Color State Description US1 2 green On Power is being supplied to power input P1...

Страница 6: ...0 OR 1 Connect Power PushPull to the power port of FreeCon 2 Connect Data FO PushPull to the data port of FreeCon 3 Start Config tool FreeCon CFG on your PC which is connected to the same Profinet 4 Click on IP address to change it the shown IP is a sample 5 Push set buttom to adopt the new values Actual Soft Firmware www weidmueller de downloads software Industrial_Ethernet ...

Страница 7: ...5 A 24VDC Power throughput 2x24VDC 16A at 20 C Connection Power PushPull connector Reverse Polarity Protection Present Physical Characteristics Housing IP65 protection metal case Dimensions 112x52x130mm Weight 780g Installation Wall Mounting 4x M4x10 Environmental Limits Operating Temperature 20 to 55 C Storage Temperature 40 to 70 C Ambient Relative Humidity 5 to 95 non condensing Regulatory Appr...

Страница 8: ...dmüller gives no warranty or guarantee as to the interoperability in specific systems or as to the fitness for any particular purpose To the extent permitted by law any claims for damages and reimbursement of expenses based on whatever legal reason including contract or tort shall be excluded Where not expressly stated otherwise in this warranty the general conditions of purchase and the expressiv...