Weidmüller FreeCon Active PROFINET-POF-Media Converter Скачать руководство пользователя страница 1

 

 

 

 

 

FreeCon Active 
PROFINET-POF-Media Converter 

 

 

IE-CDM-V14MRJSCP/VAPM-C

 

Содержание FreeCon Active PROFINET-POF-Media Converter

Страница 1: ...FreeCon Active PROFINET POF Media Converter IE CDM V14MRJSCP VAPM C ...

Страница 2: ... The FreeCon Active s tough IP65 metal housing is perfectly suited for harsh industrial applications Revision history Version Date Changes 1 0 26 01 2013 First Edition Contact address Weidmüller Interface GmbH Co KG P O Box 3030 32720 Detmold Klingenbergstraße 16 32758 Detmold Germany Phone 49 0 5231 14 0 Fax 49 0 5231 14 2083 E Mail info weidmueller com Internet www weidmueller com Copyright noti...

Страница 3: ...T POF Media Converter 7 2 1 Electrical Characteristics 7 2 2 Internal CPU 7 2 3 Mechanical characteristics 8 3 Installation and Connectors 9 3 1 Mounting 9 3 2 Power Connection 10 3 3 Data connection 11 3 4 Grounding earthing 12 4 Setup and Network Configuration 13 4 1 Setup with GSDML File 13 4 2 Setup with Weidmüller FreeCon CFG 14 4 3 Using a web browser to access the device 15 4 4 SNMP configu...

Страница 4: ...xtended Diagnostic Capabilities 19 6 1 PLC Integration 19 6 2 Web browser diagnostics 23 7 Status and Maintenance 24 7 1 LED indicators 24 8 Technical Specifications 26 9 Warranty 29 Appendix A Pin assignments for data and power port 30 ...

Страница 5: ...e operating instructions have been written for trained and qualified personnel who are familiar with the valid regulations and standards applicable to the field of application 1 3 Accuracy of the technical documentation These operating instructions have been written with due care and attention Unless otherwise required by law we do not guarantee that the data images and drawings are accurate or co...

Страница 6: ...ate electrical equipment must not be disposed through the normal waste disposal channels Electrical equipment must then be disposed of and recycled separately All devices that fall under the directive must feature this logo What we can do for you Weidmüller offers you the possibility of returning your old device to us at no extra charge Weidmüller will then professionally recycle and dispose your ...

Страница 7: ...c path they also provide an early warning mechanism indicating when e g a robot s cabling needs to be replaced The illustration below shows how FreeCon Active PROFINET FO Media Converter fits into a typical robotics application Figure 1 The FreeCon Active PROFINET FO Media Converter positioned in a typical robot application A Weidmüller FreeCon Active PROFINET FO Media Converter on axis 1 of the r...

Страница 8: ...acteristics The device measures 112 mm by 52 mm by 130 mm It has two PushPull power ports and two PushPull network ports as shown in the illustration below The FreeCon Active PROFINET POF Media Converter is not intended for outdoor usage Figure 2 FreeCon Active PROFINET POF Media Converter ...

Страница 9: ...he illustrations below for the actual mounting dimensions Four screws must be used to mount the FreeCon Active PROFINET POF Media Converter to a wall Use the device itself as a guide to mark the proper locations for the four screws We recommend using M4x10mm screws or longer Figure 3 Mounting dimensions ...

Страница 10: ... power cabling The cabling should be implemented in accordance with the PROFINET Installation Guideline for Cabling and Assembly PROFINET Cabling and Interconnection Technology downloadable on www profibus com We recommend labeling the wiring to all connected devices Use Weidmüller s IE PS VAPM 24V power plug order number 1068910000 to connect to the FreeCon Active PROFINET POF Media Converter Fig...

Страница 11: ...been implemented with full duplex technology Rx Tx RD TD DEVICE 1 POF Media Converter DEVICE 2 RJ45 Tx Rx TD RD Figure 5 Rx to Tx cabling between connected devices and FreeCon Active PROFINET FO Media Converter Use Weidmüller s PushPull STEADYTEC data plug the IE PS V14M 2SC POF order number 1191550000 for the SCRJ fiber connection Figure 6 The IE PS V14M 2SC POF data plug WARNING This is a Class ...

Страница 12: ...70000 for the RJ45 copper connection Figure 7 The IE PS V14M RJ45 FH P data plug 3 4 Grounding earthing Proper earthing and wire routing are important in order to limit the effects of electromagnetic interference EMI The earthing on the FreeCon Active PROFINET POF Media Converter is established using the functional earth from the power plug ...

Страница 13: ... is essential that the FreeCon Active PROFINET POF Media Converter has a valid TCP IP configuration so that it can function properly on the network The TCP IP settings are stored internally in the system file ethcfg cfg These settings can be changed using one of the methods described below 4 1 Setup with GSDML File The FreeCon Active PROFINET POF Media Converter is normally installed within a faci...

Страница 14: ...igure the FreeCon Active PROFINET POF Media Converter This software which can be downloaded free from the Weidmüller website scans the Ethernet and displays any FreeCon Active PROFINET POF Media Converter that it finds The program can access the settings of any device on the network using UDP on port 3250 Carry out the following steps to run this utility 1 Connect the PushPull power connector to t...

Страница 15: ...using FreeCon CFG the web server hosted on the converter can be accessed using the assigned IP address Use a web browser installed on a PC that is on the same subnet The Web interface can be used to Manually display the device properties Firmware Version Series Number und MAC ID Change settings IP address Subnet mask or Gateway address Figure 11 Properties of FreeCon Active PROFINET POF Media Conv...

Страница 16: ...agement Information Base MIB 4 5 FTP configuration The FreeCon Active PROFINET POF Media Converter can be configured by FTP client Get access via FTP client to the IP address of the FreeCon Active PROFINET POF Media Converter and download the file ethcfg cfg You can change parameters like IP address and subnet mask with a standard editor and then upload the new file to the converter This kind of c...

Страница 17: ...he firmware file via FTP Use the command ftp IP address to establish the FTP connection to the converter and confirm the user login with Enter The confirmation user logged in appears With the command put filename you can transfer the new firmware to the device NOTE The transfer of the firmware needs only a few seconds and then follows a check and the update of the converter which needs up to 2 min...

Страница 18: ...e GSDML file which is located on the converter will also be updated with the firmware update process Check after installation whether you have the latest version Detailed description of the firmware update you will find at www weidmueller com ...

Страница 19: ...er These values are normally accessed through the controller software e g Step 7 They can also be accessed directly by connecting to the FreeCon Active PROFINET POF Media Converter s web server 6 1 PLC Integration The diagnostic information can be handled by PROFINET PLCs The following description is exemplary for the integration of the FreeCon Active POF Media Converter in the Siemens Step 7 conf...

Страница 20: ... and other devices by selection via the right mouse button and the menu point insert object Optional you can use the hardware catalogue Figure 15 Insert PROFINET devices The next step is to set the IP address and device names to make them addressable in the PROFINET network Figure 16 Edit IP addresses ...

Страница 21: ...igure 17 Properties window for adapting the device name Figure 18 Assigning device name Now load the project into the PLC and switch it to the run mode If the PROFINET network is well configured the two LEDs SF and BF will be switched off You can see the diagnostic information of each part in the module information window Step 7 ...

Страница 22: ...Extended Diagnostic Capabilities 22 1324440000 00 01 13 Figure 19 Step 7 device information ...

Страница 23: ...window and navigate to the diagnostics page The following diagnostics screen will be shown Figure 20 Browser based diagnostics view Temperature Displays the current temperature of the inbuilt fiber transceiver Vcc Displays the supply voltage of the inbuilt fiber transceiver Power Link Margin The difference in dB between received optical power and the minimum optical power needed to overcome path l...

Страница 24: ... and transmission okay Yellow Blinking at 1 Hz PROFINET I O flash blink identification both LEDs blink at the same time Off No link or P1 fiber optic RX power out of range functionality enabled by the PROFINET I O controller If one of the P LEDs is off please check if cabling is connected correctly 7 1 2 The US1 and US2 LEDs These LEDs are controlled by the hardware as follows Colour Status Indica...

Страница 25: ...ified That the proper IP Address is set if not set by the I O Controller That the hardware configuration is correct 7 1 4 The BF LED This LED is used to indicate a bus failure Colour Status Indicates Red On solid No connection to network links down on port 1 and port 2 Red Blinking at 0 5 Hz No connection to I O controller Off Connection to I O controller usually the PLC is established If the BF L...

Страница 26: ...nm Max TX 2 dBm Min TX 8 5 dBm RX sensitivity 25 dBm Link Budget 16 5 dB Typical distance 50 m using P980 1000 POF cable 160 dB km Saturation 1 dBm Power Input voltage 18 30 VDC Input current 0 125 A 24 VDC Power connection PushPull Power connector Reverse polarity protection Yes Max Power 16 A per Port Physical characteristics Housing main material alloy profile Cover zinc diecast painted Degree ...

Страница 27: ...Technical Specifications 1324440000 00 01 13 27 Ambient conditions Operating temperature 20 C 55 C Storage temperature 40 C 70 C Ambient relative humidity 5 95 non condensing ...

Страница 28: ...latory Approvals Safety UL 1863 Emissions EN 61000 6 4 Class A ESD EN61000 4 2 Level 3 RF EN61000 4 3 Level 3 Burst EN61000 4 4 Level 3 Surge EN61000 4 5 Level 3 CRFI EN61000 4 6 Level 3 Shock IEC 60068 2 27 Hammer IEC 60068 2 75 Vibration IEC 60068 2 6 ...

Страница 29: ...roduct to replace the defective one Save where expressly described otherwise in writing in this catalogue product description Weidmüller gives no warranty or guarantee as to the interoperability in specific systems or as to the fitness for any particular purpose To the extent permitted by law any claims for damages and reimbursement of expenses based on whatever legal reason including contract or ...

Страница 30: ...nments for data and power port Data port P1 SCRJ Fiber Optic TX RX transmit receive Data port P2 RJ45 8 1 Pin assignments 1 2 3 4 5 6 7 8 TD TD RD RD according to PROFINET spec these pins should be left unconnected On the converter they are terminated by an RC network towards FE Functional Earth ...

Страница 31: ...Appendix A Pin assignments for data and power port 1324440000 00 01 13 31 Power port 1 2 3 4 5 Pin assignments 1 2 3 4 5 L1 N1 L2 N2 FE US1 US1 US2 US2 FE ...

Отзывы: