Troubleshooting
2571390000/01/11.2017
32
8.3 Replacing a cutting blade
CAUTION
Risk of injury posed by sharp blades
►
Use forceps to change the blades.
►
Dispose of the removed blades in a sepa-
rate container.
All present blades must be replaced each time
the knife is changed.
►
Remove the protective cover and the chute.
2
1
Figure 8.1 Cutting blade
► Loosen the fixing screws (
1
) (Allen key 2.0 mm).
►
Remove the blades (
2
).
►
Align the new blades so that the bevelled edges are
turned away from one another.
Figure 8.2 Aligning the blades
►
Insert the new blades.
► Screw both fixing screws back on tightly.
►
Reattach the chute and the protective cover.
8.4 Replacing the fuses
► Make sure that the machine is switched off.
►
Remove the power plug.
1
Figure 8.3 Opening the fuse compartment
►
Lever the fuse compartment (
1
) out of the mains filter
unit using a slotted screwdriver.
►
Replace both fuses with new ones (2 x T2AH250V).
► Put the fuse compartment back into the mains filter unit.
Содержание 9023100000
Страница 2: ......
Страница 18: ...2571390000 01 11 2017 18 ...
Страница 34: ...2571390000 01 11 2017 34 ...
Страница 50: ...2571390000 01 11 2017 50 ...
Страница 66: ...2571390000 01 11 2017 66 ...
Страница 82: ...2571390000 01 11 2017 82 ...
Страница 98: ...2571390000 01 11 2017 98 ...
Страница 114: ...2571390000 01 11 2017 114 ...
Страница 130: ...2571390000 01 11 2017 130 ...
Страница 146: ...2571390000 01 11 2017 146 ...
Страница 162: ...2571390000 01 11 2017 162 ...
Страница 178: ...2571390000 01 11 2017 178 ...
Страница 194: ...2571390000 01 11 2017 194 ...
Страница 210: ...2571390000 01 11 2017 210 ...