Operation and Service Instructions
3
Version: 10.02.2020
Direction of inclination
3 Loading
IT IS IMPERATIVE TO FOLLOW:
•
Always load the support stand evenly from the center over the entire area in use.
▪
Always load the plate stand so that the plates are leaned in the
direction of the small angles at the bottom of the tubes.
Exception:
trapezoidal support. This must be loaded equally from
the left and right.
▪
The only function of the angles is to ensure a minimum distance
between the slab and the tube in order to achieve an ideal load on
the tubes.
•
Make sure that the tube in rail A and the corresponding tube in rail B are equally loaded by the plate. This is
guaranteed if the supporting edge of the plate is exactly perpendicular to the two rails.
•
Avoid knocks and bumps against the tubes. Lean the slabs against the tubes cautiously and with a suitable lifting tool.
3.1 Carrying capacity
Always lean the slabs against the tubes as steeply as possible. Make sure that you do not exceed the maximum allowed
distance from the following table. This distance depends on the panel thickness.
d: Thickness of plate
h: Height of the slab
r: Height of the tubes
a: max. Distance between slab and tube
d
r
h
a