8. OPERATION
8�1
Safety instructions for operation
Please note:
Subsequent mentions of descriptions and position numbers refer to
Chapter 3. Product overview / product description on page 11
Î
Apply pressure to the WEH
®
Connector only once it has been connected to a test
piece.
Î
Do not use excessive force when actuating.
Î
Follow the steps in
exactly
the right order when connecting and disconnecting the
WEH
®
Connector.
Î
Attach and detach the WEH
®
Connector only when it is not under pressure.
Î
Connect the WEH
®
Connector only to test pieces in full working order.
Î
Align the WEH
®
Connector correctly with the test piece to prevent any damage to the
seal on the test piece and damage to the connector.
Î
Once the connection has been made, always test the connection by tugging a little
on the WEH
®
Connector to make sure that is fully engaged and that the clamping
jaws are gripping correctly before introducing the pressurized test medium.
Î
The clamping jaws of the WEH
®
Connector are designed to grip the test piece. Keep
fingers and other objects away from the clamping jaws when actuating the
connector.
Caution:
Possible consequences of non-compliance are:
– Risk of fingers being crushed when connecting
– Risk to human safety and risk of damage to property by parts detaching at high
pressure
– Risk to human health by media being released at high pressure
– Risk to human safety by hoses not being secured
Î
The WEH
®
Connector is not fitted with an integrated shut-off valve and thus will
not prevent loss of test medium when disconnecting. Therefore it is important to
disconnect the connector only under absolutely safe conditions.