WEGE WZ6012 Скачать руководство пользователя страница 1

 
 

数控直流稳压电源使用说明

 

Instructions  for  use  of  numerical  control  DC 

stabilized voltage power supply 

 

English Instruction Manual 

         

 

 

 

 

         

   

         

 

         

中文说明书

 

 

Содержание WZ6012

Страница 1: ...1 Instructions for use of numerical control DC stabilized voltage power supply English Instruction Manual...

Страница 2: ...2 WZ6012 2021 10 08 V1 0...

Страница 3: ...3 1 1 5 1 1 1 5 1 1 2 5 1 2 7 1 3 7 1 4 7 1 4 1 8 1 4 2 8 1 4 2 1 8 1 4 2 2 9 1 4 2 3 10 1 4 2 4 10 1 4 2 5 11 WIFI APP 13 1 APP 13 2 13 2 1 14 2 2 APP 14...

Страница 4: ...4 2 2 1 14 2 2 2 APP 15 2 2 3 16 2 2 4 17 3 APP 19 3 1 WZ6012 19 3 2 APP 20 APP 22 24 1 25...

Страница 5: ...5 1 1 1 1 1 1 1 2...

Страница 6: ...6 9 70V 80 OTP WIFI USB RS485...

Страница 7: ...7 1 2 1 3 1 8 APP PC 4 USB RS485 WIFI 1 4 WIFI WIFI...

Страница 8: ...8 1 4 1 1 4 2 OK 1 4 2 1...

Страница 9: ...9...

Страница 10: ...10 1 4 2 2 4 M1 M2 M3 M4 1 4 2 3 2S 1 4 2 4...

Страница 11: ...11 1 4 2 5 MENU 1 2 1 255 3 COM WIFI COM RS485 USB WIFI WIFI 4 COM 9600 19200 38400 57600 115200 WIFI 115200 5 6...

Страница 12: ...12 7 8 9 logo 10 0 6 11 12 13...

Страница 13: ...13...

Страница 14: ...14...

Страница 15: ...15...

Страница 16: ...16...

Страница 17: ...17...

Страница 18: ...18...

Страница 19: ...19 APP WZ6012 WZ6012 APP WIFI...

Страница 20: ...20...

Страница 21: ...21 APP 5 6...

Страница 22: ...22...

Страница 23: ...23...

Страница 24: ...24 win7 Net framework4 USB USB RS485 USB RS485...

Страница 25: ...90H A0H B0H C0H D0H 80H 90H 0x20 1 0 1 0x21 1 1 255 0x22 1 0 OFF 1 ON 0x71 1 0 1 0x72 1 0x23 1 0 OFF 1 ON 2 0 CV 1 CC 3 0 1 2 3 4 0x24 1 2 3 4 5 6 7 0x25 0x26 1 2 0 1 3 0 1 4 0 1 5 0 6 6 0 1 7 0 TTL 1...

Страница 26: ...26 8 0 1 9 0 1 2 3 10 0 9600 1 19200 2 38400 3 57600 4 115200 0x29 1 2 3 4 5 6 7 8 9 10 0x2A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 0x2B 0x2C 1 2 3 4 5 6 7 8 9 10 11 12 13 14...

Страница 27: ...er supply Product model WZ6012 Revision time 2020 10 08 Version No V1 0 Version No note in order to better understand and use all functions of the product and obtain a good user experience please read...

Страница 28: ...28 1 1Operation panel description 1 1 1 Front Panel 1 1 2 Rear panel matters needing attention...

Страница 29: ...be burnt When the current or power or temperature is too high the fan is turned on otherwise the fan is turned off When the temperature is higher than 80 degrees the OTP is displayed and the output i...

Страница 30: ...ple display interfaces Extended external USB RS485 WIFI Integrated panel for easy assembly Multiple protection 1 4Operating instructions After power on if WIFI mode is set in the menu connect WIFI ser...

Страница 31: ...structions In the menu operation the red shadow is the currently selected menu and the blue is not selected Press the direction key to move the cursor or switch the menu and then press OK to confirm P...

Страница 32: ...etting Press the current setting key Current setting is selected curve display interface setting will automatically pop up Set the selected bit to display in reverse red Shift left and right buttons R...

Страница 33: ...ting is selected curve display interface setting will automatically jump out Press the protection setting key again The overcurrent protection setting is selected and the selected bit is displayed in...

Страница 34: ...the communication status flag turns green at this time the key is automatically locked the communication is disconnected the flag bit turns white and the key is automatically unlocked 1 4 2 4Scale adj...

Страница 35: ...oose digital classic interface or curve display interface 2 The device address can be set from 1 255 3 The communication interface can be set as COM or WIFI interface COM port is the interface connect...

Страница 36: ...the output will be turned off automatically 8 When the button sound is turned on press the button buzzer to prompt and when it is turned off press the button to mute 9 After opening the boot image th...

Страница 37: ...n is restored This operation can be performed when there is an exception in the use process to restore the factory settings Press the left and right keys to confirm or cancel and press the OK key to e...

Страница 38: ...38...

Страница 39: ...39...

Страница 40: ...40 Click the menu icon to open the sideslip interface click the address selection and the operation is as shown in the figure...

Страница 41: ...41 The language option in the sideslip interface is similar to the option operation and address selection Click to enter the interface for operation...

Страница 42: ...42...

Страница 43: ...43...

Страница 44: ...ted here that the app should be opened first and then the WZ6012 should be opened to set the communication interface mode of WZ6012 The app is only used in WIFI mode The specific operation is shown in...

Страница 45: ...45 Please refer to the following picture for specific operation steps and pay attention to the operation sequence in the next step 2 Wait until the IP address appears on the WZ6012 interface...

Страница 46: ...46...

Страница 47: ...47...

Страница 48: ...48...

Страница 49: ...d above systems need to be installed with net framework 4 or above If the computer does not have one please install it yourself This software is developed by our company without virus If the antivirus...

Страница 50: ...rns red after success Then choose the device address Click to connect device Indicator state turns green after work Establish connection between software and equipment for real time communication Thro...

Страница 51: ...n return parameter 90H If the setting parameter is wrong or the parameter overflows Then return parameterA0H If the command cannot be executed Then return parameter B0H If the command is invalid Then...

Страница 52: ...set system parameters 1 Device address 2 Power on interface 0 No 1 WZ 3 Power on default output 0 No 1 has 4 Sound flag 0 turns off key sound 1 turns on key sound 5 Backlight brightness 0 6 6 Languag...

Страница 53: ...hest byte of the current capacity value 11 Read the next lower byte of the current capacity value 12 Read the low byte of the current capacity value 13 Read the high byte of the current temperature va...

Отзывы: