ABNORMALITY 

POSSIBLE CAUSES 

CORRECTION 

Stator winding becomes very 

hot under load 

 

Insufficient cooling due to dirty water 
channels 

 

Clean the water passage channels 

 

Overload 

 

Measure the stator current. Reduce the 
load. Analyze the motor application 

 

High number of starts or moment of inertia 
too high 

 

Reduce the number of starts 

 

Voltage too high, therefore,  the iron losses 
increase 

 

Do not exceed 110% of the rated voltage, 
except when otherwise specified on the 
nameplate 

 

Voltage too low, therefore, the current is 
very high  

 

Check the supply voltage and the voltage 
drop on the motor 

 

Interruption in a power cable or in a winding 
phase 

 

Measure the current in all the phases and, if 
necessary, correct it 

 

Rotor drags against the stator 

 

Check the air-gap, operating conditions 
(vibration etc.), bearing conditions 

 

The operating condition does not 
correspond to the nameplate data  

 

Keep the operating condition according to 
the nameplate or reduce the load 

 

Unbalance in the power supply (blown fuse, 
wrong command) 

 

Check if there is voltage unbalance or 
operation with two phases and correct it 

 

Dirty windings 

 

Clean the windings 

 

Rotation direction is not compatible with the 
used fan  

 

Check the fan regarding to the motor 
rotation direction 

Noisy operation when 

uncoupled 

 

Unbalance 

 

Perform new balancing 

 

Interruption in one phase of the stator 
winding 

 

Measure the current of all connecting cables 

 

Fastening screws are loose 

 

Retighten and lock the screws 

 

The rotor balancing conditions become 
worse after the assembly of the coupling 

 

Balance the coupling 

 

Resonance in the foundation 

 

Adjust the foundation 

 

Motor frame deformed 

 

Check flatness of the base 

 

Bent shaft 

 

Check the rotor balancing and eccentricity 

 

Air-gap is not even 

 

Check shaft warping or rolling bearing wear  

 

11

 

ENVIRONMENTAL INFORMATION 

 

11.1

 

PACKAGE 

 
Electric motors are supplied in cardboard, polymer, wood 
or metallic material packages. These materials are 
recyclable or reusable and must be properly disposed 
according to the current regulations of each country. All 
the wood used in the packaging of WEG motors comes 
from reforestation and receives anti-fungal treatment. 

 

11.2

 

PRODUCT 

 
Electric motors, under the constructive aspect, are 
manufactured mainly with ferrous metals (steel, cast iron), 
nonferrous metals (copper, aluminum) and plastic. 
The electric motor, in general, is a product that has a long 
useful life; however, when it must be disposed, WEG 
recommends that the materials of the packaging and of 
the product be properly separated and sent for recycling. 

The non-recyclable materials must be properly disposed 
according to the environmental regulations, i.e., in 
industrial landfills, co-processed in cement kilns or 
incinerated. The service providers for recycling, disposal in 
industrial landfills, co-processing or incineration of waste 
must be properly licensed by the environmental agency of 
each state to carry out these activities. 
 

11.3

 

HAZARDOUS WASTE 

 

Grease and oil waste used to lubricate the bearings 
should be disposed, according to the instructions of the 
relevant environmental agencies, because its improper 
disposal can cause impacts to the environment. 
 
 
 
 

 

Содержание WGM20 Series

Страница 1: ...utomation I Energy I Transmission Distribution I Coatings Three phase induction motors cooled by water jacket WGM20 line Squirrel cage rotor Horizontal and Vertical Installation Operation and Maintena...

Страница 2: ......

Страница 3: ...Installation Operation and Maintenance Manual Document Number 10005256831 Material number 14108242 Model WGM20 Language English Revision 01 March 2018...

Страница 4: ......

Страница 5: ...efore we recommend that you read this manual carefully before proceeding with the installation operation or maintenance of the motor in order to ensure safe and reliable operation of your equipment an...

Страница 6: ......

Страница 7: ...17 3 3 3 6 Bearings 17 3 3 3 7 Terminal boxes 17 3 3 3 8 Cleanliness and conservation of the motor during storage 17 3 3 3 9 Inspections and records during storage 17 3 3 3 10 Predictive preventive m...

Страница 8: ...ng 28 4 8 8 Couplings 28 4 8 8 1 Direct coupling 28 4 8 8 2 Gear coupling 28 4 8 8 3 Belt drive 28 5 STARTING 30 5 1 DIRECT ON LINE STARTING 30 5 2 DIRECT ONLINE STARTING FREQUENCY 30 5 3 LOCKED ROTOR...

Страница 9: ...assembly 40 7 10 9 4 NDE vertical bearing disassembly 40 7 10 9 5 Bearing assembly 41 7 10 9 6 Bearing insulation 41 7 10 10Rolling bearing replacement 41 7 10 11Bearing protection 41 7 10 11 1 Protec...

Страница 10: ......

Страница 11: ...s with major special features is necessary consult WEG All procedures and standards contained in this manual must be observed in order to ensure proper operation of the motor and the safety of the per...

Страница 12: ...n for example keep people away avoid contact of children etc Those responsible for the safety of the installation must ensure that Only qualified personnel install and operate the equipment They have...

Страница 13: ...ls within the limits in accordance with the IEC60034 1 standard Voltage may vary within a range of 10 of the rated value Frequency may vary within a range of 5 to 3 of the rated value Figure 2 1 Volta...

Страница 14: ...the final assembly A complete visual inspection of the motor must be carried out after removing the package The shaft locking system must be removed just before the installation and stored to be used...

Страница 15: ...heaters must remain powered during storage in order to avoid moisture condensation inside the motor Any damage to the paint or corrosion protection of the machined parts must be repaired 3 3 1 Outdoor...

Страница 16: ...tation and fungus formation the package must be protected in the storage place by spraying it or painting it with appropriate chemicals The package preparation must be prepared carefully by an experie...

Страница 17: ...erminal boxes must also be inspected observing the following aspects The inside must be dry clean and free of any dust accumulation The contact elements cannot present corrosion The seals must be in p...

Страница 18: ...inal boxes X X Inspect the seals and gaskets X X BEARINGS Rotate the shaft X Relubricate the bearing X Disassemble and clean the bearing If the storage period exceeds 2 years 3 3 4 Preparation for com...

Страница 19: ...operation it must be protected against moisture high temperatures and dirt thus avoiding impacts on the insulation resistance The winding insulation resistance must be measured before putting the moto...

Страница 20: ...n index allows the assessment of the motor insulation conditions DANGER In order to avoid accidents the winding must be grounded immediately after measuring the insulation resistance 4 4 6 Conversion...

Страница 21: ...ure the working conditions are considered special and the motor specific documentation must be consulted The Table 4 4 shows the numerical values and the composition of the acceptable temperature at t...

Страница 22: ...connecting cables must be shielded and the shield must be grounded The installation of the signal cables should be done in a linear manner avoiding turns and should not be installed near of the power...

Страница 23: ...32 148 70 149 07 149 45 130 149 82 150 20 150 57 150 95 151 33 151 70 152 08 152 45 152 83 153 20 140 153 58 153 95 154 32 154 70 155 07 155 45 155 82 156 19 156 57 156 94 150 157 31 157 69 158 06 158...

Страница 24: ...motor cooling system nameplate must be strictly followed The water inlets and outlets must not be obstructed because it can cause overheating or even lead to burning the motor 4 6 1 1 Cooling system...

Страница 25: ...x with the cover 3 NOTE The stator terminal box allows for 180 rotation in horizontal motors and 90 in vertical motors Figure 4 5 Stator terminal box Figure 4 5 legend 1 Stator terminal box 2 Connecti...

Страница 26: ...ust be tightened The rail closer to the driving pulley must be mounted so that the positioning bolt is placed between the motor and the driven machine The other rail must be mounted with the bolt in t...

Страница 27: ...rregularities on the dial gauge tip Choosing the upper vertical point as 0 half of the difference between the dial gauge measurements at the 0 and 180 points represents the vertical coaxial error In c...

Страница 28: ...or removed with the aid of proper devices and never by means of rudimentary tools such as hammers sledgehammers etc ATTENTION Dowel pins nuts washers and leveling shims may be supplied with the motor...

Страница 29: ...evented by applying a resin like material such as pitch for instance The belt tension must be just enough to prevent slippage during operation NOTE Belts too tensioned increase the load on the shaft e...

Страница 30: ...uction motors have a high starting current the time spent to accelerate loads with high inertia results in a quick rise of the motor temperature If the intervals between successive starts are too shor...

Страница 31: ...the space heaters 2 Set the protections in the control panel 3 Turn ON the water cooling system checking the necessary flow and pressure and the temperature of the cooling water 4 Rotate the motor sh...

Страница 32: ...when the purchase contract specifies different values The vibration measurements are carried out on the NDE and DE bearings in the vertical horizontal and axial directions When the customer sends the...

Страница 33: ...ance measurements must be done at regular intervals especially during humid weather and after prolonged motor stoppages Low values or sudden variations in the insulation resistance must be investigate...

Страница 34: ...r an increase in cooling water temperature it indicates an increase of scale formation in the channels which over time can clog and impair the water circulation In this case the cooling water channels...

Страница 35: ...or Table 8 2 and locked with chemical lock 7 6 VIBRATION Any evidence of increase in the unbalance or vibration of the motor must be investigated immediately 7 7 MOTOR OUT OF OPERATION When the motor...

Страница 36: ...o make the lubrication with the motor in operation in order to ensure the renewal of the grease in the rolling bearing housing If that is not possible due to the presence of rotating parts near the gr...

Страница 37: ...es for regular applications Manufacturer Grease Constant operating temperature C Multiplication factor Exxon Mobil UNIREX N3 Lithium Complex Soap 30 to 150 0 90 Shell ALVANIA RL3 Lithium Soap 30 to 12...

Страница 38: ...perties of the mixture are within the property ranges of the greases individually In general greases with the same type of soap are compatible however depending on the proportion of the mixture there...

Страница 39: ...rew 7 that fasten the grease flinger 5 Remove the grease flinger 4 6 Remove the DE end shield of the motor 2 7 Remove the bearing 3 8 Remove the internal bearing cap 6 if is necessary 7 10 9 2 NDE hor...

Страница 40: ...the bearing 3 8 Remove the internal bearing cap 5 if is necessary 7 10 9 4 NDE vertical bearing disassembly Figure 7 9 NDE vertical bearing Figure 7 9 legend 1 Shaft 2 NDE end shield 3 Bearing 4 Grea...

Страница 41: ...tions in the reverse order Figure 7 10 External bearing cap 7 10 9 6 Bearing insulation The motor has insulated NDE end shield and shaft grounding brush to prevent the passage of electric current thro...

Страница 42: ...hreaded connection cable 1 Motor accessory 2 Accessory connection cable Accessory location Accessory disassembly assembly Pt 100 of water inlet and outlet Water leakage sensor Horizontal Motors Water...

Страница 43: ...and coil heads support the shaft on DE and NDE sides 8 1 1 Disassembly 1 Disconnect the cables of the bearings temperature sensors in the accessories terminal box 2 Disassemble the DE bearing 6 and th...

Страница 44: ...rminal box 2 Disassemble the DE bearing 6 and the motor DE end shield 4 as described in item 7 10 9 3 3 Remove the KMT nut 16 that fasten the NDE bearing 4 Disassemble the NDE bearing 8 and the motor...

Страница 45: ...3 510 338 382 254 M30 3 5 693 461 520 346 M33 3 5 937 622 703 466 M36 4 1207 802 905 602 M42 4 5 1929 1280 1447 960 M48 5 2892 1918 2170 1440 NOTE The resistance class is normally indicated on the hea...

Страница 46: ...tions x BEARINGS Control of noise vibration leaks and temperature x Lubricant quality control x Lubricant change According to the period indicated on the bearing nameplate COOLING SYSTEM Verification...

Страница 47: ...the power cables The stator current oscillates under load with double the slip frequency The motor presents a humming noise during starting Rotor winding is interrupted Check and repair the rotor win...

Страница 48: ...ose Retighten and lock the screws The rotor balancing conditions become worse after the assembly of the coupling Balance the coupling Resonance in the foundation Adjust the foundation Motor frame defo...

Страница 49: ...www weg net 14108242 Installation operation and maintenance manual Squirrel cage motor WGM20 Line l 49 12 DECLARATION OF CONFORMITY...

Страница 50: ...nty in connection with this sale and is in lieu of all other warranties expressed or implied written or oral There are no implied warranties of merchantability or fitness for a particular purpose that...

Страница 51: ...remona Phone 39 374 340 404 www ferrarisrl it STIAVELLI IRIO S P A Via Pantano Blocco 16 Capalle 50010 Campi Bisenzio FI Phone 39 55 898 448 www stiavelli com JAPAN WEG ELECTRIC MOTORS JAPAN CO LTD Yo...

Отзывы: