Digital and Analog Inputs and Outputs
CFW501 | 12-3
12
P0231 – Signal Function AI1
P0236 – Signal Function AI2
P0241 – Signal AI3 Function
Adjustable
Range:
0 = Speed Reference
1 = Not Used
2 = Not Used
3 = SoftPLC
4 = PTC
5 = Feedback 1 Main PID
6 = Feedback 2 Main PID
7 = Not Used
8 = Feedback External PID
9 = Not Used
Factory
Setting:
P0231 = 5
P0236 = 8
P0241 = 0
Properties:
cfg
Access groups
via HMI:
I/O
Description:
These parameters define the analog input functions.
When the 0 option is selected (Speed Reference), the analog inputs can provide the reference for the motor,
subject to the specified limits (P0133 and P0134) and to the action of the ramps (P0100 to P0103). However,
in order to do so, it is also necessary to configure parameters P0221 and/or P0222 by selecting the use of
the desired analog input. For further detail, refer to the description of those parameters in
COMMAND AND SPEED REFERENCE on page 7-1
Option 3 (SoftPLC)
configures the input to be used by the programming done in the memory area reserved
for the SoftPLC function. For further details, refer to the SoftPLC user’s manual.
Option 4 (PTC)
configures the input for motor temperature monitoring by means of the reading of a PTC type
sensor, when this sensor is present in the motor. In order to do so, it is also necessary to configure one analog
output (AO) as current source to feed the PTC. More details on this function are presented in
Содержание CFW501 V1.8X
Страница 2: ......
Страница 8: ...Summary...
Страница 34: ...General Information 2 4 CFW501 2...
Страница 38: ...About the CFW501 3 4 CFW501 3...
Страница 42: ...HMI and Basic Programming 4 4 CFW501 4...
Страница 58: ...Identification of the Inverter Model and Accessories 6 4 CFW501 6...
Страница 72: ...Logical Command and Speed Reference 7 14 CFW501 7...
Страница 76: ...Available Motor Control Types 8 4 CFW501 8...
Страница 108: ...Functions Common to all the Control Modes 11 14 CFW501 11...
Страница 134: ...Digital and Analog Inputs and Outputs 12 26 CFW501 12...
Страница 148: ...Faults and Alarms 14 12 CFW501 14...