Keypad (HMI)
4-1
4
4 KEYPAD (HMI)
4.1 KEYPAD (HMI)
Through the keypad (HMI) it is possible to command the inverter, visualize and adjust all the parameters. It
presents a navigation manner similar to the one used in cell phones, with options to access the parameters
sequentially or by means of groups (menu).
"Left Soft key": Function defined by the text
directly above on the display.
1. Increases the parameter contents.
2. Increases the speed.
3. Selects the previous group of the Parameter
Group list.
Controls the motor speed direction.
Active when:
P0223 = 2 or 3 in LOC and /or
P0226 = 2 or 3 in REM.
Selects between LOCAL or REMOTE
situation.
Active when:
P0220 = 2 or 3.
It accelerates the motor following the acceleration ramp up to
the speed defined in P0122.
It keeps the motor at this speed as long as pressed.
When released it decelerates the motor following the
deceleration ramp down to stop.
Active when al the conditions below were fulfilled:
1. Run/Stop = Stop.
2. General Enable = Active.
3. P0225 = 1 in LOC and/or P0228 = 1 in REM.
Decelerates the motor following the deceleration
ramp, down to stop.
Active when:
P0224 = 0 in LOC or
P0227 = 0 in REM.
Accelerates the motor following the acceleration
ramp.
Active when:
P0224 = 0 in LOC or
P0227 = 0 in REM.
1. Decreases the parameter contents.
2. Decreases the speed.
3. Selects the next group of the Parameter
Group list.
Right "Soft key": Function defined by the text
directly above on the display.
Figure 4.1 -
HMI keys
Battery:
The life expectation of the battery is of approximately 10 years. In order to remove it rotate the cover located at
the back of the keypad (HMI). Replace the battery, when necessary, by another of the CR2032 type.
NOTE!
The battery is necessary only for clock-related functions. In the event of the battery being discharged
or not installed in the keypad (HMI), the clock time becomes incorrect and the alarm A181 – "Invalid
clock value" will be indicated every time the inverter is powered.
Содержание CFW-11 Series
Страница 2: ......
Страница 54: ...2 4 2 General Information ...
Страница 58: ...About the CFW 11 3 3 4 ...
Страница 74: ...Inverter Model and Accessories Identification 5 14 6 ...
Страница 86: ...Inverter Model and Accessories Identification 6 12 6 ...
Страница 94: ...Available Control Types 8 2 8 ...
Страница 118: ...VVW Control 10 8 10 ...
Страница 182: ...Functions Common to All the Control Modes 12 26 12 ...
Страница 220: ...Dynamic Braking 14 4 14 ...