weedingtech FoamStream M1200 Скачать руководство пользователя страница 34

M1200 

 User manual 

 English (EU) 

 01/03/2018 -  ISSUE 2

 

 

15.

 

Warranty 

(a)  The  following  is  an  inexhaustive  summary  of  relevant 
aspects  of  the  standard  terms  and  conditions  of  Weeding 

Technologies Ltd (“WTL”) and is subject to those terms and 

conditions and to any special terms and conditions agreed 

between  the  parties.  Where  this  summary  and  WTL’s 

standard  terms  and  conditions  conflict,  those  terms  and 
conditions  take  precedence  (and  any  special  terms  and 

conditions take precedence both over WTL’s standard terms 

and conditions and over this document). You are advised to 
read  the  full  terms  and  conditions  including  so  as  to  take 
note of further exclusions of liability.  

(b) In no case (without express written agreement, and save 
as required by  law)  does WTL accept any  liability towards 
any  perso

n  other  than  the  person  (“you”)  who  originally 

made the purchase from WTL or in respect of any alleged 
defect  not  notified  by  you  to  WTL  within  12  months  from 
delivery.  

You are notified that the standard warranty period given by 
the manufacturer is 12 months from delivery. 

(c)  You  must  inspect  all  goods  thoroughly  with  7  days  of 
delivery. Subject to the rules set out in section 3 below, any 
claim must be notified to WTL within 7 days of delivery or 
(subject to clause (b) above) in the case of any defect which 
is not reasonably apparent on inspection then within seven 
days of the defect coming to your attention (or of the date 
when the defect reasonably should have been apparent to 
you, if earlier). 

(d) Subject to section 3 below, WTL will have no liability if 
you do not comply with the above. 

(e)  WTL’s  options,  in  cases  where  it  is  liable,  include 

repairing  or  replacing  defective  goods  and  allowing  you 
credit for them. If WTL exercises such an option it has no 
further liability. In any event, the liability of WTL is limited 
to parts, freight and a limited amount of labour as set out in 

WTL’s  standard  terms  and  conditions.  Labour  in  excess  of 

such limits will be at your cost in any event. 

(f) You must, if so requested in writing by WTL, at your risk 
promptly return any goods the subject of any claim and any 
packing materials securely packed and carriage paid to WTL 
for  examination.  (If  the  claim  is  substantiated,  WTL  will 
normally reimburse these costs) 

(g) If any repairs, modifications, or adjustments are carried 
out upon goods other than by WTL or personnel that hold a 
valid training certificate or are an authorised sub-contractor   
then WTL will have no liability in respect of those goods. 

(h) WTL does not accept any liability to you for any loss or 
damage  of  any  nature  except  as  expressly  stated  in  the 
standard  terms  and  conditions  (or  in  such  terms  and 
conditions  as  may  be  specially  agreed  between  you  and 
WTL).  This  means  among  other  things  that  WTL  has  no 
liability  for  consequential  losses,  property  damage, 
penalties,  liquidated,  exemplary  or  aggravated  damages, 
downtime,  loss  of  goodwill,  capital  costs  or  any  pure 
economic loss. 

(i)  Subject  to  section  3  below,  WTL  does  not  accept  any 
liability for defects resulting from wear and tear, accident, 
improper  use  or  use  except  in  accordance  with  the 

Содержание FoamStream M1200

Страница 1: ...USER MANUAL ENGLISH EU 01 03 2018 ISSUE 2...

Страница 2: ...M1200 User manual English EU 01 03 2018 ISSUE 2...

Страница 3: ...1200 _________________ 19 9 FOAMSTREAM APPLICATION KILLING WEEDS ____________________________ 21 9 1 HOSE REEL _____________________________________________ 21 9 2 SPEED ______________________________...

Страница 4: ...Viz vest is suggested as best practice IT IS THE RESPONSIBILITY OF THE OPERATOR TO WEAR APPROPRIATE PPE Never operate the machine without checking that there are adequate supplies of clean diesel clea...

Страница 5: ...te tank When the water reaches 95 degrees centigrade a valve opens allowing water to flow from the lance 12 lpm 12 bar and a venturi mixer opens to allow Foamstream concentrate to be injected at a rat...

Страница 6: ...hydraulic connections water supply water return one electrical connection water sensor and 13 bolts when the tank is attached to the unit An automatic hose reel is located inside the unit to allow the...

Страница 7: ...2018 ISSUE 2 Figure 2 Perspective view of the M1200 Num Description 1 Control panel 2 Lance 3 Water tank 4 Exhaust hood 5 Hose reel orifice 6 Forks entry 7 Left cover panel 8 Right cover panel 9 Traff...

Страница 8: ...English EU 01 03 2018 ISSUE 2 8 Figure 3 Left inside view of the M1200 Num Description 1 Diesel particulates filter Optional extra 2 Water pump 3 Diesel generator vent CAUTION HOT 4 Diesel generator C...

Страница 9: ...f the inside of the M1200 um Description 1 Lance solenoid valve 2 Pressure gauge 3 Main flow switch 4 Return to tank flow switch 5 Pressure relief valve PRV 6 Lance pressure switch 7 Venturi 8 Foam fi...

Страница 10: ...2 10 Figure 5 Closed control box left open right Figure 6 Detail of the switches on the front panel Num Description 1 Emergency stop 2 Main contact switch 3 Boiler reset button 4 Power light 5 Diesel...

Страница 11: ...and can be used to kill larger weeds Foam cover and hence heat retention on weeds is easier to achieve on prostrate plants that are near the ground Tall plants should be trodden down either by foot o...

Страница 12: ...ies and their size 4 3 Caution poisonous weeds Some poisonous weeds such as common ragweed Senecio jacobaea may still be attractive to animals after treatment with Foamstream When treating any area wh...

Страница 13: ...a blanket of foam The density of the plants and foliage is a very important aspect for the operator to be aware of as this also impacts on the speed of operation It should be noted As the height and...

Страница 14: ...f clean water Water filter is clean and free from debris Water feed valve is connected and in the on inline position The water return pipe and water level sensor is connected Air has been bled from wa...

Страница 15: ...e first time of the day please use Air bleed full If you just took a break or want to perform an additional air bleed please select Air bleed partial When bleeding the machine the trigger must be push...

Страница 16: ...0 seconds 2 Press this button to purge the M1200 for 10 seconds 3 Indication message 4 Air bleed status indicator 5 Menu access Figure 13 Bleed screen of the PLC Figure 14 Start screen of the PLC Num...

Страница 17: ...M1200 User manual English EU 01 03 2018 ISSUE 2 17 Figure 15 Running screen of the PLC...

Страница 18: ...n on the top right hand side of the screen The screen in will appear Figure 16 Menu screen Num Description 1 Return to main page 2 Go to summary screen 3 Purge 4 Language selection 5 Fault summary pan...

Страница 19: ...ystem fault see below GREEN READY LIGHT When this light is illuminated the M1200 is ready for use If the green light is not illuminated the water may need heating amber light will be on or there is a...

Страница 20: ...indicates the boiler is too hot The M1200 should be switched off and checked by a competent service engineer GREEN AND AMBER WITH FLASHING RED FAULT LIGHT A flashing red fault light with illuminated...

Страница 21: ...RRY If the operator moves too quickly over the vegetation the required volume of hot water and foam may not have penetrated or been applied correctly Total vegetation control will not have been achiev...

Страница 22: ...rs will become familiar with determining whether weeds have been treated correctly Broad leaf weeds will go floppy and wilt similar to boiled cabbage In most cases these will go darker in colour Grass...

Страница 23: ...evel and the pump stops Wait until the red fault light switches off Turn the isolator switch to A Turn the generator key switch to A DO NOT USE THE EMERGENCY STOP TO STOP THE MACHINE OTHER THAN IN AN...

Страница 24: ...Return to tank flow switch Green colour indicates that the sensor is seeing a signal and grey or red that it doesn t Red colour does not necessarily mean that there is an issue with the sensor Normal...

Страница 25: ...Yellow Same as above Outlet pressure too low Red The lance valve is open and the flow is ok but there is no signal from the pressure switch Please control the pressure on the pressure gauge of the sid...

Страница 26: ...ss Start Boiler starting up Yellow Nothing Water Boiler pre heating Yellow The boiler is warming up the water to reach 95 and will then open the lance valve You have nothing to do Air bleeding in prog...

Страница 27: ...CAUSE REMEDY Generator will not start no lights Battery is flat Charge battery No fuel in tank Refill tank and bleed fuel system Air in the fuel pipe Prime fuel using the in line hand pump The PLC wi...

Страница 28: ...Fill up tank with foam Breathing screw of the foam tank too tight air not getting through Loosen the breathing screw on top of the cap of the foam tank Foam filters clogged Clean foam filters using ho...

Страница 29: ...setting if required Check and de scale coil if necessary Change particulates filter cartridge if applicable EVERY 500 HOURS 12 MONTHS MAXIMUM Change generator oil filter Change generator air filter C...

Страница 30: ...is not full of water This could result in a serious damage to the machine if the tank is attached to the frame THE M1200 SHOULD NOT BE LIFTED WITH A FULL TANK OF WATER Before driving the user should m...

Страница 31: ...User manual English EU 01 03 2018 ISSUE 2 14 Schematics Figure 22 Foam and water schematics WATER TANK WATER FILTER WATER PUMP VENTURI FOAMTANK FOAMFILTER 1 FOAMFILTER 2 BOILER PRESSURE RELIEF VALVE...

Страница 32: ...M1200 User manual English EU 01 03 2018 ISSUE 2 32 Figure 23 Fuel schematics DIESEL TANK DIESEL FILTER GENERATOR HANDPUMP LEVEL SENSOR BOILER...

Страница 33: ...Electrics schematics KEY SWITCH GENERATOR ISOLATOR CONTROLBOX CONTROL PANEL BOILER PUMP LANCEVALVE PRESSURE SWITCH TEMPERATURE SENSORINLET TEMPERATURE SENSOROUTLET LANCEFLOW SWITCH BYPASSFLOW SWITCH...

Страница 34: ...uld have been apparent to you if earlier d Subject to section 3 below WTL will have no liability if you do not comply with the above e WTL s options in cases where it is liable include repairing or re...

Страница 35: ...or alteration in factory foam additive dosage settings Please note that it is not to be inferred or implied from the fact that WTL may supply you with any technical means of altering the settings for...

Страница 36: ...E certified Noise measurements and certification are available upon request Some specific versions of M1200 are CSA and UL certified Documents and specification are available upon request Weeding Tech...

Отзывы: