40
WECON technology Co., Ltd
P.Init
Parameter restore
to factory
setting value
When using the
system parameter
initialization
function
(P10-02=1)
The servo drive is in the
process of parameter
restoration to factory
settings
Error
Parameter error
The parameter
setting exceeds the
limit (or does not
allow it to exceed
the limit)
Prompt that the parameter
setting exceeds the limit
Table 5-3 Parameter setting display
5.2.4 Fault display
The panel can display current or historical fault and warning codes. For analysis and
troubleshooting of faults and warnings, please refer to
When a single fault or warning occurs, the panel immediately displays the current fault or warning
code;
when multiple faults or warnings occur, the highest fault code is displayed. When a fault occurs,
when switching from the auxiliary function to the parameter display function, the corresponding
fault or warning code will be displayed. You can view the current fault and warning codes and the
past five fault and warning codes through the monitor display on the panel.
Table 5-4 and Table 5-5 respectively show the case of panel warning display and fault display
Display
Name
Content
Parameter modification that
needs to be powered on again
Modified the parameters that need
to be re-powered on to take effect
Table 5-5 Fault display cases
Display
Name
Content
Motor overload protection Motor overload protection
Table 5-4 Warning display cases
5.2.5 Monitor display
After the servo drive is powered on or the servo enable is ON, you can press the "Mode" key to
enter the monitor display mode.
Display
Monitoring
volume
Name
Unit
Meaning
U0-02
Servo
motor
speed
rpm
Indicates the actual operating
speed of the servo motor,
expressed in decimal.