Wecon VD2 SA Series Servo Drives User Manual (Full V1.0)
118
WECON technology Co., Ltd
time is continued;
P05-12
Positioning
completion
threshold
Operation
setting
Effective
immediately
800
1~65535
Positioning
completion
threshold
Equival
ent
pulse
unit
P05-13
Positioning
approach
threshold
Operation
setting
Effective
immediately
5000
1~65535 Positioning
approach threshold
Equival
ent
pulse
unit
P05-14
Position
detection
window time
Operation
setting
Effective
immediately
10
0~20000
Set the detection
window time for
positioning
completion
ms
P05-15
Positioning
signal hold
time
Operation
setting
Effective
immediately
100
0~20000
Set the hold time of
positioning
completion output
ms
P05-16
Rotation
detection
speed
threshold
Operation
setting
Effective
immediately
20
0~1000
Set the motor
rotation signal
judgment threshold
rpm
P05-17
Speed
consistent
signal
threshold
Operation
setting
Effective
immediately
10
0~100
Set speed consistent
signal threshold
rpm
P05-18
Speed
approach
signal
threshold
Operation
setting
Effective
immediately
100
10~6000 Set speed approach
signal threshold
rpm
P05-19
Zero speed
output signal
threshold
Operation
setting
Effective
immediately
10
0~6000
Set zero-speed
output signal
judgment threshold
rpm
P05-20
Torque
arrival
threshold
Operation
setting
Effective
immediately
100
0~300
The torque arrival
threshold must be
used together with
%