Wecon VD2 SA Series Servo Drives User Manual (Full V1.0)
97
WECON technology Co., Ltd
Figure 7-3 Notch characteristics, notch width, and notch depth
Figure 7-4 Frequency characteristics of notch filter
Function
code
Name
Setting
method
Effective
time
Defaults
Range
Definition
Unit
P04-05
1st notch
filter
frequency
Operation
setting
Effective
immediately
300
250~5000
Set the center frequency of
the 1st notch filter.
When the set value is
5000, the function of the
notch filter is invalid.
Hz
P04-06
1st notch
filter depth
Operation
setting
Effective
immediately
100
0~100
0: all truncated
100: all passed
-
P04-07
1st notch
filter width
Operation
setting
Effective
immediately
4
0~12
0: 0.5 times the bandwidth
4: 1 times the bandwidth
-