LX3V-4AD
7
WECON TECHNOLOGY CO., LTD.
b3: Hardware error
A/D
converter
or
other
hardware failure
Hardware normal
b10: Digital range error
Digital output value is less than
-2048 or more than +2047
Averaging is normal. (between
1 and 4096)
b11: Averaging error
Number of averaging samples is
4097 or more or 0 or less
(default of 8 will be used)
Averaging is normal. (between
1 and 4096)
b12: Adjust prohibit
Prohibit-(b1, b0) of BFM #21 is
set to (1, 0)
Permit-(b1, b0) of BFM #21 is
set to (0,1)
NOTE:
b4 to b7, b9 and b13 to b15 are undefined.
5)
Identification Code BFM #30
The identification (or ID) code number for a Special Function Block is read using the FROM
command.
This number for the LX3V-4AD unit is K2011 or K2010.
The user’s program in the PC can use this facility in the program to identify the special function
block before commencing data transfer from and to the special function block.
NOTE:
Values of BFM #0, #23 and #24 are copied to EEPROM memory of the LX3V-4AD. BFM #21 and
BFM #22 are only copied when data is written to the gain/offset command buffer BFM #22.
Also, BFM #20 causes writing to the EEPROM memory. The EEPROM has a life of about 10,000
cycles (changes), so do not use programs which frequently change these BFMs.
Because of the time needed to write to the EEPROM memory, a delay of 300 ms is required
between instructions that cause a write to the EEPROM. Therefore, a delay timer should be
used before writing to the EEPROM a second time.
5.
Defining gain and offset
Gain determines the angle or slope of the calibration line, identified at a digital value of 1000.
(a) Small gain: Large steps in digital readings
(b) Zero gain: Default is 5V or 20mA.