allation & Operating Manual 

VN Series  

Non-Clog Pumps

Congratulations On Your Choice 

In Purchasing This Webtrol Pump 

Its Quality is unsurpassed in material and workmanship and has been factory tested. 

If properly installed, it will give many years of trouble free service.

10/15 Edition

Содержание VN50C49

Страница 1: ...on Clog Pumps Congratulations On Your Choice In Purchasing This Webtrol Pump Its Quality is unsurpassed in material and workmanship and has been factory tested If properly installed it will give many years of trouble free service 10 15 Edition ...

Страница 2: ...asin instructions If pump is being retrofitted to an existing rail system accessory parts may be required Consult the factory and advise make and model of rail system being used 1 Warning Under no circumstances should cable be pulled while the pump is being transported or installed Attach a chain or rope to the grip and install the pump 2 This pump must not be installed on its side or operated in ...

Страница 3: ... range do not continue with station start up The voltage problem must be corrected prior to proceeding Warning Sewage pump can develop dangerous and harmful fumes Make note that fumes developed by sewage are very dangerous to our health and even fatal 1 The VN non clog submersible sewage pump has a semi closed impeller design and ranges from 5 10 HP 230V 460V 3Phase voltage 2 Turn the operating sw...

Страница 4: ...trical shock Only qualified electrician should repair this unit Improper repair could result in fatal electrical shock Disassembly of Pump 4 Maintenance Preventive annual inspections 1 Sewage series pump should be checked yearly for debris and or build up which might interfere with ON or OFF position of variable level float switches 2 Check pressure output voltage current and other specifications ...

Страница 5: ...ve piping Gate valve is closed to far Open gate valve System Trouble Shooting Operates but stops after a while Possible Cause Of Trouble Corrective Action Prolonged dry operation has activated motor protector and caused pump to stop Raise stop water level High liquid temperature has activated motor protector and caused pump to stop Lower liquid temperature Reverse rotation Correct rotation see Ope...

Страница 6: ...f High Level Alarm Inches Note Float location to be measured from the bottom of the tank Other Information Thank You For Purchasing VN Non Clog pump We at Webtrol are constantly working on new products to make your job easier while making your systems more efficient reliable and affordable Your opinion means a lot to us so please let us know what you think about our V Series Wastewater Pump Weber ...