background image

61318 0204

Natural Gas Dual Burner Station Owner’s Guide

WARNING: Do not store or use gasoline 

or other flammable liquids or vapors 
within 25 feet (8m) of this appliance.

DANGER

If you smell gas:
1. Shut off gas to the appliance.
2. Extinguish any open flames.
3. Open lid.
4. If odor continues, keep away from the

appliance and immediately call your
gas supplier or your fire department.

Leaking gas may cause a fire or
explosion which can cause serious bodily
injury or death, or damage to property.

NOTICE TO INSTALLER: These instructions
must be left with the owner and the owner
should keep them for future use.

WARNING: Follow all leak-check 
procedures carefully in this manual 
prior to burner station operation. Do 
this even if burner station was 
dealer-assembled.

WARNING: Do not try to light this 

appliance without reading "Lighting" 
instructions section of this manual.

THIS GAS APPLIANCE IS DESIGNED FOR
OUTDOOR USE ONLY.

Y

OU MUST READ THIS

O

WNER

S

G

UIDE BEFORE OPERATING YOUR BURNER STATION

Vieluxe

®

Slide-In Dual Burner Station

(Model #: 36152)

Vieluxe

®

Countertop Dual Burner Station

(Model #: 37152)

Содержание Vieluxe 36152

Страница 1: ...us bodily injury or death or damage to property NOTICE TO INSTALLER These instructions must be left with the owner and the owner should keep them for future use WARNING Follow all leak check procedure...

Страница 2: ...young children away while it is in use You should exercise reasonable care when operating your Vieluxe burner station It will be hot during cooking or cleaning and should never be left unattended or...

Страница 3: ...S 6 TO EXTINGUISH 6 MANUALLY LIGHTING THE LEFT RIGHT BURNERS 7 TO EXTINGUISH 7 GENERAL MAINTENANCE 8 CHECK FOR GAS LEAKS 8 REMOVE CONTROL PANEL 8 REINSTALL CONTROL PANEL 10 REINSTALL BURNER CONTROL KN...

Страница 4: ...s manual Deterioration or damage due to severe weather conditions such as hail hurricanes earthquakes or tornadoes discoloration due to exposure to chemicals either directly or in the atmosphere is n...

Страница 5: ...st be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psig 3 5 kPa Turn OFF your Vieluxe burner station when the gas supply...

Страница 6: ...Both burner valves must be in the OFF position before turning on the gas supply If the valves are not in the OFF position gas will flow to the burners This condition can cause a fire or explosion res...

Страница 7: ...nob in and turn clockwise to ensure that it is in the OFF position Lift the cover to fully open before attempting to light the left or right burner Turn on the gas supply and select which burner s you...

Страница 8: ...from the burner station WARNING The gas connections of your Vieluxe burner station have been factory tested We do however recommend that you leak check all gas connections before operating your Vielux...

Страница 9: ...l connections should be rinsed with water after checking for leaks WARNING Make sure all burner control knobs are in the OFF position 1 Turn on the gas supply Check for leaks by wetting the connection...

Страница 10: ...trol knobs 1 in through the bezels onto the valve stems Push the igniter 4 through the control panel so that the threads appear replace the igniter nut 3 and the igniter button 2 You will need 2 contr...

Страница 11: ...lue Check that all burner components are in place Check that the orifice is not obstructed 2 3 4 1 Replace igniter battery Parts required 1 AA alkaline battery Unscrew igniter button from front of con...

Страница 12: ...s gas supply off Is fuel hose bent or kinked Inspect burner ring slots for obstructions Inspect burner base for obstructions Does burner light with a match Is burner ring properly installed Cure Turn...