background image

THIS GAS APPLIANCE IS DESIGNED 

FOR OUTDOOR USE ONLY.

42370 US 10/01/05

NG 

LOCATING YOUR GRILL

When determining a suitable location for your Summit

®

 gas grill installation, give attention to concerns such as exposure to wind, proximity to traffi c paths, and 

keeping any gas supply lines as short as possible. Never locate the Summit

®

 gas grill in a garage, breezeway, shed, under an unprotected overhang, or other 

enclosed area. Locate the grill and structure so there is enough room to safely evacuate the area in case of a fi re.

CLEARANCE FROM SURFACES OR STRUCTURES

WARNING: Clearance from any surface or structure is 

24 inches (609.6 mm) from the back and sides of the grill. 
Refer to “Typical Gas Supply Installation” before starting 
installation.

WARNING: The structure, “island”, countertops, and 

adjacent work areas for the built-in grill installation must be 
built from noncombustible materials only.

NOTE: If you have questions on what materials are considered noncombustible, 
contact your local building materials supplier or fi re department.

 

A

ny 
S

ur

face

Any Surface

24 inches (61 cm) Any Surface

24 inches 

(61 cm)

24 inches 

(61 cm)

Grill Frame

Note: For a countertop treatment: Recommended 3/4 inch 
(19.1 cm) overhang. Notch front edge for frame to fully 
slide in.

27 inches (685.8 mm) min. for 
lid clearance

1

3

2

 BUILT-IN NG GAS GRILL INSTALLATION GUIDE

PLATINUM   D4 / D6 

SUMMIT

®

BUILT-IN STRUCTURE CUTOUT DIMENSIONS
ALL DIMENSIONS ARE TO FINISHED SURFACES.

 

WARNING: All countertop fi nished surfaces must be 

constructed of a noncombustible material.

Built-In Cutout Dimensions

D4

D6

Tolerances

1

30 

1/4

˝

38 

1/4

˝

1/4

”   - 

1/4

˝

2

34 

1/4

˝

34 

1/4

˝

1/4

”   - 

1/4

˝

3

21˝

21˝

1/4

”   - 

1/4

˝

42370

42370_NG BIinstll.indd   1

9/23/05   11:08:10 AM

Содержание PLATINUM 42370

Страница 1: ...tarting installation WARNING The structure island countertops and adjacent work areas for the built in grill installation must be built from noncombustible materials only NOTE If you have questions on what materials are considered noncombustible contact your local building materials supplier or fire department Any Surface Any Surface 24 inches 61 cm Any Surface 24 inches 61 cm 24 inches 61 cm Gril...

Страница 2: ...3 4 inch overhang Notch front edge for frame to fully slide in 6 1 4 3 3 4 Gas Inlet 24 min 2 4 m in Clearance from any surface or structure is at least 24 inches from the back and sides of the grill 27 inches min distance from front edge of the cutout for open lid clearance 10 1 2 min Side Burner Opening 6B GENERAL CONSTRUCTION DETAILS Summit Built In unit and all other accessory units should be ...

Страница 3: ...Bottom Shelf 1 Rear Panel Assembly 1 Left Door 1 Right Door 1 Warming Rack 1 Warm Up Rack 1 Front Frame Rail 1 Rear Frame Rail 1 Right Enclosure Panel 1 Left Enclosure Panel 1 Front Vent Panel 1 Lid 1 Cookbox 1 OR Rear Vent 1 4B 6B ...

Страница 4: ...nch 1 1 2 inch Bolts 1 4 x 20 x 1 2 inch Bolt 8 Hinge Pin 2 Hair Pin Cotter 2 Wrench 1 Nylon Washer 8 10 32 x 1 4 inch Steel Screws 5 x10 Sheet Metal Screws 3 Plastic Anchors 3 2 3 Corrugated gas line 1 Keps Nuts 1 4 x 20 Blk Zinc 2 Rotisserie Bracket Hardware 2 Right Front Vent Clip 1 Left Front Vent Clip 1 1 2 Flare Gasket 2 3 8 Flare Gasket 2 Handle 2 Handle Hardware 4 PARTS LIST CONTINUED 6B 4...

Страница 5: ...it Platinum D4 NG Built In 091905 17 18 19 21 38 39 40 62 63 64 45 27 42 4 14 20 22 23 24 16 13 57 56 60 3 6 26 65 12 5 7 55 25 15 58 41 43 44 46 47 49 50 51 10 9 8 52 53 54 11 66 68 69 70 76 77 28 29 30 31 33 34 35 67 36 71 72 74 75 61 59 37 73 32 ...

Страница 6: ...anel 32 Handle Assembly 33 Bottom Shelf 34 Toe Kick Vent 35 Left Vent Bracket 36 Left Door Assembly 37 Right Door Assembly 38 Hair Pin Cotter 39 Lid Assembly 40 1 4 20 x 1 1 4 inch Bolt 41 IR Rain Cover Hardware 42 12 inch Cook Grate 43 IR Rain Cover 44 10 24 x 1 2 inch Stainless Steel Screw 45 Right Flavorizer Bar Assembly 46 IR Burner 47 IR Cover Box 48 Warming Rack 49 Thermocouple 50 IR Gas Lin...

Страница 7: ...t Platinum D6 NG Built In 092005 17 20 21 22 24 42 43 44 58 65 66 67 68 69 47 30 52 9 10 13 12 45 4 6 7 16 23 26 27 28 29 53 55 18 14 15 51 56 60 59 62 57 3 48 49 54 46 19 11 5 25 61 71 72 73 78 79 31 32 33 35 37 38 39 70 40 74 75 76 77 36 41 63 64 34 ...

Страница 8: ...ail 33 Left Rear Panel 34 Handle Assembly 35 Left Panel 36 Door Stop 37 Bottom Shelf 38 Left Vent Bracket 39 Toe Kick Vent 40 Left Door Assembly 41 Right Door Assembly 42 Hair Pin Cotter 43 Lid Assembly 44 1 4 20 x 1 1 4 inch Bolt 45 12 inch Cook Grate 46 IR Rain Cover Hardware 47 Right Flavorizer Bar Assembly 48 IR Rain Cover 49 10 24 x 1 2 inch Stainless Steel Screw 50 Warming Rack 51 Rotisserie...

Страница 9: ...Do not fully tighten screws Clips should slide freely when installed ASSEMBLY Arrow stickers on Frame Rail 1 and Left Side Panel 2 should point toward each other shown above Door Stop Bracket 3 should be positioned as shown left ...

Страница 10: ...10 3 4 ASSEMBLY ...

Страница 11: ...11 5 ASSEMBLY ...

Страница 12: ... a bead of silicone sealant 1 around the perimeter and front edges of the grill that are in contact with the island structure This will prevent moisture seepage The sealant you use must have a temperature rating above 120 F 48 8 C Any Surface 24 inches 610mm 24 inches 610mm 24 inches 610mm Frame Note For a countertop treatment Recommended 3 4 inch 19 1 mm overhang Notch front edge for frame to ful...

Страница 13: ...13 7 4B 6B 1 3 2 ASSEMBLY ...

Страница 14: ...14 8 1 2 4B 6B ASSEMBLY ...

Страница 15: ...15 Match Holder a b c 4B 6B 9 ASSEMBLY ...

Страница 16: ...16 10 ASSEMBLY 11 1 4 Drill Bit ...

Страница 17: ...17 12 13 ASSEMBLY 14 15 ...

Страница 18: ...ions In absence of Local Codes you must conform to the latest edition of National Fuel Gas Code ANSI Z223 1 NFPA54 This grill is designed to operate at 4 5 inches of water column pressure A manual shut off valve must be installed outdoors and be accessible not in the built in structure An additional manual shut off valve indoors should be installed in the branch fuel line in an accessible location...

Страница 19: ... area while you check for gas leaks This will result in a fire or explosion which can cause serious bodily injury or death and damage to property GAS SUPPLY Corrugated Gas Line to Manifold Cap Optional Side Burner Regulator Hard piped gas supply top view a 1 Corrugated Gas Line to Manifold Cap Optional Side Burner Regulator Hard piped gas supply top view b CONNECT GAS SUPPLY A 58 inch corrugated g...

Страница 20: ...the structure are not considered vents Clean the vents periodically DANGER Failure to follow recommended minimum venting instructions can cause gas to collect in the structure in the event of a gas leak This may result in a fire or an explosion which can cause serious bodily injury or death and damage to property 2003 The following trademarks are registered in the name of Weber Stephen Products Co...

Отзывы: